The CO2 Reduction Potential Calculation through the Urban Park Construction | |
This study is to identify quantitatively the function of carbon dioxide emissions reduction due to temperature and energy reduction according to direct carbon dioxide storage, shade provision, and evaportanspiration of urban park. According to the result of study, landscape tree indicated high carbon dioxide storage effect compare to bush, in which broadleaf tree indicated higher storage function than coniferous tree. It is believed to be the storage of carbon dioxide can be increased by increasing the composition rate of forest plants in the urban park. According to the direct estimation result of carbon dioxide storage in terms of example area, storage of carbon dioxide is estimated to be "seoul a zone" 476,818.8 kg‧CO2/㎡‧yr, "anyang b zone" 186,435.7 kg‧CO2/㎡‧yr, "daejeon c zone" 262,826 kg‧CO2/㎡‧yr, "kwangju d zone" 231,657.8 kg‧CO2/㎡‧yr. The carbon dioxide storage per unit area estimated to be "seoul a zone" 3.4 kg‧CO2/㎡‧yr, "anyang b zone" 5.0 kg‧CO2/㎡‧yr, "daejeon c zone" 2.6 kg‧CO2/㎡‧yr, "kwangju d zone" 5.6 kg‧CO2/㎡‧yr. The result of indirect carbon dioxide reduction effect estimated to be "seoul a zone" 291,603.4 kg‧CO2/㎡‧yr, "anyang b zone" 165,462.4 kg‧CO2/㎡‧yr, "daejeon c zone" 141,719.2 kg‧CO2/㎡‧yr, "kwangju d zone" 154,803.4 kg‧CO2/㎡‧yr. Carbon dioxide reduction potential amount through the urban park was increased to 1.6 times to 1.8 times when calculated to the indirect effect.
Urban Tree, CO2 Storage, Temperature Reduction, Cooling Load Reduction |
Changes in the use of land such as urban development at global level instigate the emmission of 1.6 gigatons of carbon dioxide into the atmosphere every year despite the effort of United Nations Framework Convention on Climate Change (IPCC, 2000). It is estimated that 35% of the entire carbon dioxide had been discharged by human and due to changed usage of land such as urbanization or road development into the air for the last century (Turner et al., 2007). S. Korea also declared in the general meeting for the members of the 15th Conference of the Parties to the UN Framework Convention on Climate Change(UNFCCC), which was held in Copenhagen in December 2009, it will have reduced greenhouse gas emission by 30% (BAU basis) in 2020. In april, 2010, the country legislated and enacted Basic Act on Low Carbon Green Growth and has been making efforts to reduce greenhouse gas emission at the national level. Local governments set a mandatory target to reduce greenhouse gas emission and has to report the performance of the reduction to the central government every year (Lee, J.H., Lee, G.G, 2012). Because of this elevated awareness, the increase of carbon dioxide content in the atmosphere is causing considerable worry from the viewpoint related to global warming and, meanwhile, attention is giving to the capacity of park green spaces to absorb and store carbon dioxide (Laitat et al., 2000; Watson et al., 2000).
In recent years, direct CO2 absorption by urban forest trees and indirect CO2 absorption through cooling energy conservation during summer are getting more important as an alternative to tackle the issues of climatic change and energy consumption. The direct carbon reduction effect by urban forest trees is the most effective way to reduce carbon emission in terms of economy and technology (Ayman and El-Sayed, 2011; Daniel et al., 2011; Dimas and Gavriel, 2008). And it has been reported that vegetation reduces the emission of carbon (indirect absorption) into the atmosphere through the conservation of cooling energy in buildings during summer season, which is possible due to the shading and evapotranspiration (Cho, H.G., Lee, G.E., 2000). The calculation of carbon dioxide absorption by the green spaces factors in urban park requires very specific data of current status and basic research data regarding types of trees planted in the park and their growth characteristics. However, such data are limited only to a few of studies (Cho, H.G. et al., 1998; Jeong, H.D., 2009; Park, E.J., and Kang, K.Y., 2009). Furthermore, few studies have been conducted on the calculation of indirect carbon dioxide absorption through cooling/heating energy conservation.
Accordingly, the present study pays a due attention to urban park as an important CO2 sink in a city and tries to yield a formula to calculate direct carbon dioxide absorption effect by urban park and indirect carbon dioxide absorption through cooling energy conservation. Based on the calculated direct and indirect effects of carbon dioxide reduction, this study aims to demonstrate the effectiveness of urban park for the reduction of carbon dioxide.
Urban park is one constructed or designated to protect natural landscape in urban area and improve citizens' health, rest and emotional welfare in their urban life according to the Act of Urban Park and Green Space. It is classified into neighborhood park and theme park and managed accordingly. The location and size of urban park are decided in consideration of the use by neighborhood, type of use, population size of users, population allocation plan and demand analysis. Urban park is stipulated to be as big as 6㎡ per person. Mini park, historic park, cultural park and waterfront park are not subject to size requirement while children's park is specified by law to be over 1,500㎡; neighborhood park has to be 10,000 to 100 million㎡; and sports park and urban agriculture park has to be wider than 10,000㎡. Green volume in a park is legislated to conform to Clause 5 (by the size of development project) the Act of Urban Park and Green Space. According to the current laws, they do not set a standard for the function of urban park regarding carbon absorption, but it can be significantly considered that urban park can play a very significant role and function as a large-scale carbon sink, neutralizing carbon dioxide in a city.
Of the studies regarding the absorption and storage of carbon dioxide of trees, Cho, H.G. et al (2003) carried out a study on CO2 absorption of urban green spaces in Chuncheon City and found out that carbon storage per unit breast area (cm2) is 3.54kgC/㎡ on average and that unit coverage (㎡) is average 3.547kgC/㎡. Cho, H.G. and Cho, H.D (1998) calculated annual CO2 absorption of major urban landscape tree species. According to them, annual CO2 absorption of trees per unit area turned out to be 1.6-1.71t/ha/yr in natural area while that in in-town area was 0.56-0.71t/ha/yr. Kim, W.J. and Kim, U.S. (2010) reported in their study that the forests in Seoul area have 41.4tC/ha of CO2 storage of per unit area and urban park has about 17.3tC/ha of CO2 storage, which is 1/3 of that of forest. Cho, H.G. et al (2003) examined the improvement effect of urban green spaces on atmospheric environment and revealed that the average CO2 storage of planted tree per unit area was 19.4t/ha; the annual CO2 absorption 2.2t/ha/yr; and SO2 and NO2 storage were 1.9kg/ha/yr and 5.0kg/ha/yr, respectively. Park, E.J. and Kang, K.Y. (2010) calculated the carbon storage of 9 key species of trees of 90 kinds of trees planted on the avenues in Kyunggi Province. In the research, they found out that CO2 absorption of 769,505 trees subject to the experiment was 30,693tCO2/yr; CO2 absorption of 4,602 fine trees was 35tCO2/yr. Nowak and Crane (2002) reported that the urban trees in New York City stored a total of 120 tons of carbon and absorbed 770,000 tons of carbon dioxide annulary. Mcpherson et al. (2007) found out that planting a million trees in LA absorbed 28,571tCO2 on annual average and 0.029tCO2/tree/yr per tree. Moore (2009) estimated that one urban tree directly absorbed 29kgCO2 in LA and 8.9~3.6kg in New York annually on average. But few studies have been conducted to calculate CO2 storage of urban park, which is a major CO2 sink in a city and to know its CO2 storage by a variety of species of trees.
Studies have been performed on the indirect effect of CO2 reduction by the green spaces of urban park through the conservation of cooling energy. McPherson and Rowntree (1993) examined 12 cities in the United States to show that a tree (7.6m tall) conserved 100-400 kw of cooling energy annually. Placing in consideration a variety of factors such as temperature reduction by tree green spaces and the increase of wind velocity, respectively, Ca V.T. et al (1998) reported in their research upon Sacramento region that the reduction of atmospheric temperature by 1.0 ℃ in industrial areas could reduce the energy consumption of air-conditioner by 6.5% for residential purpose and by 6.7% for commercial use. Simpson (2002) revealed in his simulation test that shading plants changed the load of cooling and heating in a building by reducing incident rays. Donovan, G.H. (2009) reported that urban trees reduced energy consumption because they were close to buildings and thus directly reduced carbon dioxide emitting from the burning of fossil fuels. Mchale et al. (2007) said that direct absorption of carbon dioxide by the growth of urban trees in 4 cities, Colorado, was 75 ~ 100kgCO2 per tree and the trees indirectly inhibited the emission of carbon dioxide by forming shades over buildings and reducing the consumption of cooling energy in a building. Cho, H.G. and Lee, G.E. (2000) reported that CO2 absorption by urban green spaces set off total CO2 emission by 6 ~ 7% every year through tree planting management, soil decomposition, reduced energy consumption in Chuncheon and Kangryung City. In addition, Cho, H.G. and Ahn, T.H. (2010) found out that large shading trees facing west and east reduced cooling energy consumption by 1 to 2 % depending on the shape of building and region. Kim, D.H. (2011) revealed that when urban forest in neighborhood increased by 1m2 per person, it conserved electric energy by 0.02MWh on national average and reduced midday temperature by 1.15℃ in major metropolitan cities during summer. Although those studies have been conducted on the effect of urban trees on energy conservation, not many have performed on the conversion of the effect into indirect carbon dioxide reduction effect. In short, some of studies have paid attention to the CO2 storage and reduction of cooling energy by trees planted in urban areas, but the present study found out that there are few studies that focused on both direct CO2 storage and the reduction of cooling energy consumption that works eventually for indirect CO2 reduction by trees in urban park, which is a representative CO2 absorber.
To reduce CO2 by park & green spaces in a city that emits more than 80% of whole greenhouse gas, it is necessary to measure direct and indirect CO2 storage from the planning stage of a park and to make a plan to assign park & green spaces properly enough to increase the amount of CO2 reduction.
This study aimed to measure direct CO2 storage and indirect potential amount of CO2 reduction of a new urban park to be constructed, rather than of existing one. To this end, the present study set its research scopes as follows: first, it reviewed related literatures to know the formulas to calculate potential CO2 storage and came up with CO2 storage equations that reflect the size and ecological characteristics of trees planted in a new urban park. Second, it drew out the equations for indirect CO2 reduction that occurs from the conservation of building cooling energy by urban park. Third, it calculated potential CO2 reduction by urban park, being based on the direct and indirect CO2 reduction equations.
Within its spatial scope, this study set the urban parks located in Seoul A zone, Anyang B zone, Daejeon C zone and Kwangju D zone sector, which are scheduled to be constructed for urbanization facilities, to calculate direct and indirect CO2 reduction by urban park. To estimate the direct and indirect CO2 reduction by urban park in those areas, it was necessary to get information of individual tree in the areas, so that the study measured the dimensions of the trees on the basis of standard landscape drawings and specifications of new urban park and used them for analysis.
In the examination of the species of trees to be planted in the target area (Table 1), it turned out that the largest number of the species of trees (57 species) plans to be planted in neighborhood park and is followed by waterfront park (48 species), children's park (29 species) in Seoul A zone. In Anyang B zone, the largest number of trees in terms of the number of species is scheduled to be painted in cultural park (49 species) and is followed by neighborhood park (19 species) and children's park (14 species) in order. In Daejeon C zone, 62 species is scheduled to be planted in neighborhood park while children's park is going to have 40 different kinds of trees. In Kangju D zone, it turned out that 42 species of trees is scheduled to be planted in neighborhood park and is followed by children's park (35 species) and mini park (10 species).This comparison shows that relatively more species of trees are going to be planted in neighborhood park than other types of urban parks. In terms of the number of trees by research area, it was confirmed that neighborhood park (148,265) is going to have the largest number of trees planted in Seoul A zone while mini park (4,054) is going to have the smallest number of trees. For the number of trees by shape, broad-leaved trees (2,886 trees) and coniferous trees (91,148 trees) are relatively more planned than other types in Seoul A zone. In Anyang B zone, neighborhood park (34,233 trees) is going to have the largest number of trees planted while children's park (2,511) is going to have the smallest number of trees. For the number of trees by shape, broad-leaved trees (1,678) is planned twice more than coniferous trees (560) in Anyang B zone. In Daejeon C zone as well, neighborhood park (66,260) is scheduled to have the largest number of trees while the smallest number of trees was planned for children's park (13,411). For the number of trees by shape, broad-leaved trees (2,602) are planned 2.9 times more than coniferous trees (888) in Daejeon C zone. Kwangju D zone also showed the similar trends in terms of the total number and type of trees to be planted. Neighborhood park (3,580) is scheduled to have the largest number of trees while the smallest number of trees is planned for mini park (330). Meanwhile, more broad-leaved trees (1,250) are scheduled to be planted than coniferous trees (959).
Overview of the planting of study site
Site | Park Classification | Planting area (㎡) | Planting species(Species) | Planting populations(Tree) | Planting density(tree/㎡) | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Tree coniferous | Tree broadleaf | Shrub coniferous | Shrub broadleaf | Tree coniferous | Tree broadleaf | Shrub coniferous | Shrub broadleaf | Tree | Shrub | Total | |||
Seoul A site | Neighborhood park | Neighborhood park | 5 | 31 | 1 | 20 | 966 | 1,735 | 1,540 | 144,024 | 0.1 | 1.1 | 1.2 |
Children's park | 3,303 | 3 | 17 | - | 9 | 101 | 325 | - | 38,310 | 0.1 | 11.6 | 11.7 | |
Waterfront park | 8,903 | 1 | 27 | 1 | 19 | 41 | 762 | 130 | 31,602 | 0.1 | 3.6 | 3.7 | |
Mini park | 1,062 | 2 | 10 | 1 | 6 | 40 | 64 | 1,400 | 2,550 | 0.1 | 3.7 | 3.8 | |
Subtotal | 141,874 | 11 | 85 | 3 | 54 | 1,148 | 2,886 | 3,070 | 216,486 | 0.1 | 1.6 | 1.7 | |
Anyang B site | Neighborhood park | 14,219 | 1 | 10 | 1 | 7 | 52 | 484 | 490 | 7,510 | 0.0 | 0.6 | 0.6 |
Culture park | 21,420 | 4 | 31 | 2 | 12 | 413 | 1060 | 3740 | 29020 | 0.1 | 1.5 | 1.6 | |
Children's park | 777 | 3 | 6 | - | 5 | 60 | 81 | - | 2,370 | 0.2 | 3.1 | 3.2 | |
Mini park | 624 | 2 | 3 | - | 4 | 35 | 46 | - | 3,870 | 0.1 | 6.2 | 6.3 | |
Subtotal | 37,040 | 10 | 50 | 3 | 28 | 560 | 1,671 | 4,230 | 42,770 | 0.0 | 0.9 | 0.9 | |
Daejeon C site | Neighborhood park | 93,637 | 7 | 27 | 2 | 26 | 644 | 2,305 | 300 | 63,011 | 0.0 | 0.7 | 0.7 |
Children's park | 5,567 | 3 | 24 | - | 13 | 194 | 297 | - | 12920 | 0.1 | 2.3 | 2.4 | |
Subtotal | 99,204 | 10 | 51 | 2 | 39 | 838 | 2,602 | 300 | 75,931 | 0.1 | 0.9 | 1.0 | |
Kwangju D site | Neighborhood park | 36,594 | 3 | 27 | - | 12 | 711 | 1,028 | - | 62,465 | 0.1 | 1.7 | 1.8 |
Children's park | 3,827 | 3 | 19 | - | 13 | 237 | 172 | - | 3,580 | 0.1 | 0.9 | 1.0 | |
Mini park | 649 | 1 | 7 | - | 2 | 11 | 50 | - | 330 | 0.1 | 0.5 | 0.6 | |
Subtotal | 41,070 | 7 | 53 | 0 | 27 | 959 | 1,250 | - | 66,375 | 0.0 | 0.7 | 0.7 |
To examine direct CO2 storage capacity by the trees and green spaces in a urban park, which is a major CO2 sink, and indirect CO2 reduction through the conservation of cooling energy by urban park, the present study reviewed previous studies regarding the calculations of CO2 storage by trees planted in parks and set a research model that can calculate direct and indirect potential CO2 reduction by the trees planted in the new urban parks (see Figure 1).
Based on the model, hypotheses were established as followed.
H 1: The trees planted and green spaces formed in a new urban park will store CO2 and, by doing so, function as a key CO2 sink for a city.
H 1-1: It will be possible to measure CO2 storage if CO2 storage formula can be derived from the dimensions (diameter at breast height for landscape tree) and number of tree for bush tree) of trees specified in the landscape drawing of a new park.
H 2: The trees planted and green spaces formed in a new urban park will indirectly function to store CO2 through by reducing the consumption of cooling energy and thus reducing CO2 emitted from the burning of fuel.
H 2-1: It will be possible to measure indirect potential CO2 reduction if CO2 reduction formula can be derived from the reduction of cooling energy by trees specified in the landscape drawing of a new park and indirect CO2 reduction equation according to it.
![](JKIEAE_2014_v14n2_87_f003.jpg)
Fig. 1
Research Model
CO2 storage per individual tree is generally calculated using biomass allometric equation by species. In Korea, the equation has been known only for some species of urban tree. Cho, H.G. (1999) calculated each of biomass allometric equation of Pinus densiflora, Pinus koraiensis, Quercus mongolica, Populus tomentiglandulosa T. Lee, Rhododendron schlippenbachii, Rhododendron mucronulatum and Lespedeza bicolor var. japonica NAKAI . Cho, H.G. and Ahn, T.H. (2001) used an infrared gas analyzer to measure CO2 exchange rate and derived a formula to calculate annual carbon dioxide absorption. However, domestic researches are limited to some species of landscape trees and shrubs, so that it is hard to find a suitable biomass allometric equation in applying to diverse species of trees.
Cho, H.G. (2001) and Lee, K.G. (2003) summarized the existing equations and developed a simplified CO2 storage formula that uses the diameter of a tree as variable (diameter at breast height for landscape tree and diameter at root for shrub). The formula is a clue to calculating CO2 storage using the dimensional information of a tree. However, a landscape drawing for park or others contains root diameter of landscape tree and crown width for shrubs, so that it is hard to apply the formula. Accordingly, the present study altered the formula into a regression model that sets as variable root diameter for landscape tree and number of tree for shrub so as to make it possible to measure CO2 storage on the basis of the dimensional information of trees from the landscape drawing of a new park. To acquire necessary data, the study measured both the root diameter and breast diameter of 216 coniferous trees (6 species) and 131 broad-leaved trees (15 species) planted in Bundang Park and compared them to develop a formula that uses root diameter as variable. For shrubs, 120 coniferous shrubs (3 speceis) and 156 broad-leaved shrubs(10 species) were measured for their root diameters. Since the results showed that the gap between maximum and minimum root diameters wasn't significant, it did not make difference in the output of the regression equation using root diameter as variable. Therefore, the study premised that 2cm is an average root diameter and converted it to a formula to calculate CO2 reduction per tree. CO2 storage by urban park was estimated on the basis of the converted equation that can produce CO2 storage by using the dimensional information of trees in the landscape drawing (Equation 1).
Here, AT1is CO2 storage formula of broad-leaved tree; AT2 is CO2 storage formula of coniferous tree; AS1is CO2 storage formula of broad-leaved shrub;AS2 is CO2 storage formula of coniferous shrub.
Urban park & green spaces is known to lower temperature in neighboring area and reduce cooling energy consumption by providing shades and evapotranspiration. According to the study of Yoon, M.H. and Ahn, D.M. (2009), temperature reducing effect by green spaces reached up to 500 meters in radius from the green spaces and the temperature gap between green spaces boundary and the urban area was 0.3℃ at minimum and 1.7℃ at maximum. It was demonstrated in the study that 1℃ reduction of temperature by evapotranspiration and shading of urban green spaces can conserve residential cooling energy consumption annually by about 9% per unit and 1℃ reduction was turned out to produce 2 times greater conservation effect (Cho, H.G. and Ahn, T.W., 1999). Based on the finding, the present study attempted to estimate indirect CO2 reduction effect, besides direct CO2 storage by urban park & green spaces, through the reduced cooling energy consumption in neighboring areas to urban park, which is due to the evapotranspiration and shading provided from the park. To understand indirect CO2 reduction by the construction of urban park, a comparison of electric consumption for cooling energy during summer can be made between an area without urban park nearby and one near to it. However, the main objective of the present study is to estimate direct and indirect CO2 reduction by a new urban park to be constructed. Therefore, it is impossible to directly measure the amount of electricity used for air-conditioning in an area where a new park will be built nearby because the usage of adjacent land to the park hasn't been decided. For this reason, the study set the effect area of temperature reduction by the construction of a new park and converted the concerning area into development area (by applying residential and commercial floor area ratio) to estimate the electric consumption during summer in the development area. And it analyzed electric conservation through temperature reduction and converted it to CO2 reduction.
To be more specific, this study first reviewed and summarized the results of the studies (Mcpherson, 2007; Yoon, M.H. and Ahn, D.M., 2009) in an attempt to analyze the CO2 reduction effect on the neighborhood of a new urban park. And it set the effect range of temperature reduction by urban park & green spaces on the neighborhood (100 meters in radius) (Equation 2). It supposed that the area of (neighboring) land to be used (the study premised that the neighborhood of the new urban park is used mostly for residential and commercial purpose) is as wide as the size of the effect range of temperature reduction by urban park & green spaces. Floor space ratio (Won Unit) was applied differently by region and usage (Korea Research Institute for Human Settlements, 2010) to calculate building floor space ratio by land usage (Equation 3). Energy consumption was calculated by usage and then electricity use ratio related to cooling energy of total building energy consumption during summer was applied to Equation 4. It was again converted to the electric consumption for air-conditioning out of the total electric consumption during summer using Equation 5 in order to calculate cooling energy consumption (by air-conditioner) by building usage and building size. Based on it, Equation 6 was applied to compute cooling energy conservation (reduction of air conditioning cooling load) results from temperature reduction by the construction of urban park & green spaces. Then carbon emission coefficient, which is big as the reduction, was applied to Equation 7 to estimate the final reduction of CO2 emission.
① Effect Range of Temperature Reduction = Urban Park × 100m in Radious (2)
⋅Reviewed and used the results of the studes
(Mcpherson(2007) and Yoon and Ahn (2009))
② Development Area by Land Usage = (Equation 1) × Building Floor Space Ratio by Land Usage (3)
⋅Residential Area: Seoul (single-unit: 150%, multiunit: 250%)
Anyang (single-unit: 185%, multi-unit: 280%)
Daejeon (single-unit: 150%, multi-unit: 250%)
Kwangju (single-unit: 150%, multi-unit: 250%)
⋅Commercial Area: Seoul (central: 1,000%, noncentral: 800%)
Anyang (central: 1,087%, non-central: 913%)
Daejeon (central: 1,300%, non-central: 1,100%)
Kwangju (central: 1,300%, non-central: 1,100%)
⋅Reviewed and used the results of the study (Korea Research Institute for Human Settlements, 2010)
③ The Amount of Electricity Used by Usage = The Unit Amount of Electricity Used by Usage (Won Unit) × 0.0391 (4)
⋅The amount of electricity used by usage: single-unit
- 7.2kgoe/㎡, multi-unit - 10.2kgoe/㎡, commercial facility - 28.0kgoe/㎡
⋅ Reviewed and used the results of the study (LHI, 2011)
④ The Amount of Electricity Used for air Cooling by Usage = (Equation 4) × 0.099 (5)
⋅Electricity used for air-conditioner takes 9.9% of total electricity consumed, used the results of the study (Korea Energy Economics Institute, 2010)
⑤ Amount of Cooling Load Reduced by Urban Park & green spaces = (Equation 5) × 9.0% reduction per ℃ (6)
⋅Reviewed and used the results of the study (Mcpherson, E, G..,1988 and Ca, V. T., 1998)
(Mcpherson, E, G..,1988 and Ca, V. T., 1998)
⑥ Indirect CO2 Reduction by Urban Park & green spaces = (Equation 6) × 0.424kgC/kw×3.67 (7)
⋅Carbon Emission Coefficient from Electricity by Usage: 0.424kgc/kw (Korea Energy Economics Institute, 2010)
Annual CO2 storage in urban park is calculated with carbon storage of individual tree multiplied by 44/12 (Jeong, H.D., 2009)
The trees in Seoul A zone consists of coniferous tree (1.0%), broad-leaved tree (1.8%), coniferous shrub (5.7%) and broad-leaved shrub (91.5%). And CO2 storage by the shape of tree turned out as follows: coniferous tree (121,798.2 kg‧CO2/yr), broad-leaved tree (212,042.6 kg‧ CO2/yr), coniferous shrub (4,069.3 kg‧CO2/yr) and broad-leaved shrub (186,220.8 kg‧CO2/yr). It was found here that landscape trees took lower portion in the total tree composition of the urban parks but contributed more significantly to CO2 storage than shrubs.
The trees in Anyang B zone consists of coniferous tree (1.1%), broad-leaved tree (3.6%), coniferous shrub (1.5%) and broad-leaved shrub (93.8%). And CO2 storage by the shape of tree turned out as follows: coniferous tree (47,700.8 kg‧CO2/yr), broad-leaved tree (101,901.4 kg ‧ CO2/yr), coniferous shrub (5,415.7 kg‧CO2/yr) and broad-leaved shrub (36,790.6 kg‧CO2/y). It was found here that broad-leaved tree took much lower portion in the total tree composition but contributed relatively more to CO2 storage than broad- leaved shrub. The trees in Daejoen C zone consists of coniferous tree (1.9%), broad-leaved tree (3.7%), coniferous shrub (0.2%) and broad-leaved shrub (94.4%). And CO2 storage by the shape of tree turned out as follows: coniferous tree (59,448.4 kg‧CO2/yr), broad-leaved tree (101,901.4 kg‧CO2/yr), coniferous shrub (258.1 kg‧CO2/yr) and broad-leaved shrub (65,315.8 kg‧CO2/yr). It was found here that broad-leaved tree took 2.5 times lower portion in the total tree composition but contributed 2.6 times more to CO2 storage than broad-leaved shrub. The trees in Kwangju D zone consists of coniferous tree (16.1%), broad-leaved tree (22.7%) and broad-leaved shrub (61.1%). And CO2 storage by the shape of tree turned out as follows: coniferous tree (16,682.6 kg‧CO2/yr), broad-leaved tree (19,075.5 kg‧CO2/yr) and broad-leaved shrub (3,363.4 kg‧CO2/yr). The target areas also showed the similar trend of the contribution to CO2 storage by tree shape. Broad-leaved tree took relatively lower portion in the total tree composition but contributed more to more to CO2 storage than shrubs. This data shows that it is likely that CO2 storage capacity will be greater if the portion of landscape trees in those urban parks increases of the total tree composition. Therefore, it is necessary to increase the composition ratio of landscape trees to raise CO2 storage.
Comparison of CO2 storage capacity of each properties of trees(unit :kgCO2)
Classification | Tree coniferous | Tree broadleaf | Shrub coniferous | Shrub broadleaf | |
---|---|---|---|---|---|
Seoul A site | Neighborhood park | 97,036.9 | 122,649.6 | 2,041.2 | 123,889.3 |
Children's park | 12,175.5 | 26,078.1 | - | 32,954.2 | |
Waterfront park | 3,719.8 | 5,187.2 | 1,855.7 | 2,193.4 | |
Mini park | 8,866.0 | 58,127.7 | 172.3 | 27,183.9 | |
Subtotal | 121,798.2 | 212,042.6 | 4,069.3 | 186,220.8 | |
Anyang B site | Neighborhood park | 2,416.0 | 22,688.6 | 421.7 | 6,459.9 |
Culture park | 38,122.7 | 70,957.0 | 4,994.0 | 24,963.0 | |
Children's park | 4,278.3 | 5,296.1 | - | 2,038.7 | |
Mini park | 2,883.8 | 2,959.7 | - | 3,329.0 | |
Subtotal | 47,700.8 | 101,901.4 | 5,415.7 | 36,790.6 | |
Daejeon C site | Neighborhood park | 44,385.4 | 119,009.7 | 258.1 | 54,202.1 |
Children's park | 15,063.0 | 18,793.9 | - | 11,113.7 | |
Subtotal | 59,448.4 | 137,803.6 | 258.1 | 65,315.8 | |
Kwangju D site | Neighborhood park | 54,702.6 | 84,102.3 | - | - |
Children's park | 15,963.9 | 15,022.7 | - | 3,079.6 | |
Mini park | 718.7 | 4,052.8 | - | 283.8 | |
Subtotal | 16,682.6 | 19,075.5 | - | 3,363.4 |
In CO2 storage by urban park in Seoul A zone, it was known that neighborhood park (345,617.4 kg‧CO2/yr) having the broadest area of planted trees had the highest CO2 storage and was followed by waterfront park (85,367.3 kg‧CO2/yr). Looking into CO2 storage per unit area without considering areal effect, mini park (10.6 kg‧CO2/㎡‧yr) and children's park (10.5 kg‧CO2/㎡‧yr) had relative high level of CO2 storage per unit area. Contrarily, neighborhood park (2.7 kg‧CO2/㎡‧yr) turned out to have low CO2 storage due to its relatively low planting density of trees per unit area. CO2 storage by park in Anyang B zone showed that cultural park (139,000.4 kg‧CO2/yr), of which area of planted trees is the biggest of other orban parks in the area, had the highest CO2 storage and was followed by neighborhood park (26,650.1 kg‧CO2/yr). Looking into CO2 storage per unit area without considering areal effect, children's park (14.9 kg‧CO2/㎡‧yr) and mini park (14.7 kg‧CO2/㎡‧yr) had higher level of CO2 storage per unit area. On the contrary, neighborhood parks (1.9 kg‧CO2/㎡‧yr) turned out to have low CO2 storage due to its relatively low planting density of trees per unit area. In CO2 storage by park in Daejeon C zone, it was known that neighborhood park (345,617.4 kg‧CO2/yr), of which area of planted trees is the biggest of other urban parks in the area, had the highest CO2 storage and children's park had 44,970.6 kg‧CO2/yr of CO2 storage. However, when CO2 storage was looked into per unit area without considering areal effect, children's park (8.1 kg‧ CO2/㎡‧yr) turned out to have relatively high level of CO2 storage per unit area. In the meantime, it was proved that neighborhood park (2.3 kg‧CO2/㎡‧yr) had low CO2 storage due to its relatively low planting density of trees per unit area.
Direct CO2 storage capacity of each city park
Classification | Planting density (tree/㎡) | Average CO2 storage capacity per one tree (CO2/tree) | Amount of CO2 storage (kgCO2) | CO2 storage capacity per unit area (kgCO2/㎡) | |
---|---|---|---|---|---|
Seoul A site | Neighborhood park | 1.2 | 2.2 | 345,617.4 | 2.7 |
Children's park | 11.7 | 0.7 | 34,541.1 | 10.5 | |
Waterfront park | 3.8 | 2.9 | 11,293.0 | 10.6 | |
Mini park | 3.7 | 2.6 | 85,367.3 | 9.6 | |
Subtotal | 5.1 | 2.1 | 476,818.8 | 3.4 | |
Anyang B site | Neighborhood park | 0.6 | 3.3 | 26,650.1 | 1.9 |
Culture park | 1.6 | 4.0 | 139,000.4 | 6.5 | |
Children's park | 3.2 | 4.8 | 11,612.7 | 14.9 | |
Mini park | 6.3 | 2.2 | 9,172.5 | 14.7 | |
Subtotal | 2.9 | 3.6 | 186,435.7 | 5.0 | |
Daejeon C site | Neighborhood park | 0.7 | 3.3 | 217,855.4 | 2.3 |
Children's park | 2.4 | 3.3 | 44,970.6 | 8.1 | |
Subtotal | 1.6 | 3.3 | 262,826 | 2.6 | |
Kwangju D site | Neighborhood park | 1.8 | 2.9 | 192,536.7 | 5.3 |
Children's park | 1.0 | 8.4 | 34,065.9 | 8.9 | |
Mini park | 0.6 | 12.8 | 5,055.2 | 7.8 | |
Subtotal | 1.1 | 8.0 | 231,657.8 | 5.6 |
CO2 storage by park in Kwangju D zone showed that neighborhood park (192,536.7 kg‧CO2/yr) with broadest area of planted trees had the highest CO2 storage capacity and was followed by children's park (34,065.9 kg‧CO2/yr) and mini park (5,055.2 kg‧CO2/yr). Looking into CO2 storage capacity per unit area without considering areal effect, children's park (8.9 kg‧CO2/㎡‧yr) had higher level of CO2 storage per unit area. On the contrary, neighborhood parks (5.3 kg‧CO2/㎡‧yr) turned out to have low CO2 storage due to its relatively low planting density of trees per unit area. CO2 storage per unit area was estimated from 1.9 kg‧CO2/㎡‧yr at minimum to 10.6 kg‧CO2/㎡‧yr at maximum. This comparatively considerable gap indicates that CO2 storage capacity can be enhanced through the management of planting density of trees. Comparing with other CO2-related factors in previous studies, these CO2 storage capacities turned out to be lower than 15.1 kg‧CO2/㎡‧yr of CO2 absorption rate in natural forest (Cho, H.G., 1995) and 10.3 kg‧CO2/㎡‧yr of CO2 absorption rate in urban park (Park, E.J. and Kang, K.Y,, 2009) but similar to 6.3 kg‧CO2/㎡‧yr in urban park (Kim, H.J. and Kim, U.S., 2010) and higher than 0.154 kg‧CO2/㎡‧yr in urban arboretum and 0.251 kg‧CO2/㎡‧yr in Urban forest (Jeong, 2009)
Combining these results, it was confirmed that it is more effective to increase tree size and planting density per unit area than whole size of a park to enhance the effect of CO2 storage in urban park.
Table 4 shows the results from the calculation of indirect CO2 reduction according to reduced cooling energy load by urban park. In Seoul A zone, it was estimated that a total of 291,603.4 kg‧CO2/yr (residential: 50,073.8 kg‧CO2/yr; commercial 241,529.6 kg‧CO2/yr) will be indirectly reduced. In Anyang B zone, it was estimated that a total of 165,462.4 kg‧CO2/yr (residential: 14,209.8 kg‧CO2/yr; commercial 151,252.6 kg‧CO2/yr) will be indirectly reduced. It was also calculated that a total of 141,719.2 kg‧CO2/yr (residential: 12,302.8 kg‧CO2/yr; commercial 129,416.5 kg‧CO2/yr) will be indirectly reduced in Daejeon C zone. In Kwangju D zone, it was proved that a total of 154,803.4 kg‧CO2/yr (residential: 11,979.0 kg‧CO2/yr; commercial: 142,824.4 kg‧CO2/yr) will be indirectly reduced. Like this, CO2 reduction effect by urban park increase 1.8 times more when indirect CO2 reduction is combined with the effect. Since urban park can reduce CO2 emission as well as provides fresh climate through temperature reduction in its neighboring areas, it has considerable implication to urban environment control. Therefore, it seems necessary to consider climate control and CO2 reduction effect together with usability when urban park is designed and drawn.
Indirectly CO2 emissions capacity by the Urban parks
Classification | Power consumption (kw) | Air conditioning power consumption (KW) | Cooling load reduction (KW) | Indirect CO2 reduction (kgCO2) | |
---|---|---|---|---|---|
Seoul A site | Residential area | 1,964,604.5 | 194,495.9 | 32,208.5 | 50,073.8 |
Commercial areas | 9,476,273.6 | 938,151.1 | 155,357.8 | 241,529.6 | |
Subtotal | 11,440,878.1 | 1,132,647 | 187,566.3 | 291,603.4 | |
Anyang B site | Residential area | 539,901.6 | 53,450.3 | 9,140 | 14,209.8 |
Commercial areas | 5,746,905.6 | 568,943.7 | 97,289.4 | 151,252.6 | |
Subtotal | 6,286,807.2 | 622,394 | 106,429.4 | 165,462.4 | |
Daejeon C site | Residential area | 480,072.5 | 47,527.2 | 7,913.2 | 12,302.8 |
Commercial area | 5,050,147 | 499,964.6 | 3,244.1 | 129,416.5 | |
Subtotal | 5,530,219.5 | 547,491.8 | 91,157.3 | 141,719.2 | |
Kwangju D site | Residential area | 455,158.3 | 45,060.6 | 7,705.4 | 11,979.0 |
Commercial areas | 5,426,684.9 | 537,241.8 | 91,868.4 | 142,824.4 | |
Subtotal | 5,881,843.2 | 582,302.4 | 99,573.8 | 154,803.4 |
Upon a urban park that is an very important CO2 sink in a city emitting more than 80% of greenhouse gas, the present study attempted to and succeeded in answering the following research questions by inventing the equations to calculate direct CO2 storage capacity and indirect potential CO2 reduction through the conservation of cooling energy on the basis of the dimensional information of trees to be planned according to the landscape drawing and specification of a new urban park development: Is it possible that CO2 reduction capacity is calculated reflecting both direct CO2 storage capacity from trees planted in a urban park and indirect CO2 reduction through temperature reduction by the park? Is it possible to calculate direct and indirect potential CO2 reduction capacity by the trees and green spaces in a urban park? If possible, how much CO2 is reduced by the urban park?
Until now, the formulas used to calculate CO2 storage capacity have used diameter at breast of a tree for landscape tree and diameter at root (source) of tree for shrub. Therefore, they are not suitable to apply to trees in a new urban park. However, the present study has developed equation that can calculate CO2 storage capacity using root diameter for landscape tree and number of tree for shrub (see Equation 1 above). In addition, it analyzed the amount of electricity saved through temperature reduction by the construction of a urban park and developed the equations of potential CO2 reduction that converts the conserved amount of electricty into amont of CO2 reduced (see Equation 2 to 7 above).
According to the results of the calculations of direct and indirect CO2 reduction capacity by an urban park, landscape trees have higher level of CO2 storage capacity than shrubs by the shape of tree. Of the same landscape trees, broad-leaved trees have higher level of CO2 storage capacity than coniferous trees. Therefore, it was found out that CO2 storage of a urban park can be enhanced by increasing the portion of broad-leaved trees in the composition of trees to be planted in the park. In addition, it was known that CO2 storage capacity varies very much by urban park: 186.435.7 kg‧CO2/㎡‧yr (Anyang B zone) at minimum and 476,818.8 kg‧CO2/㎡‧yr (Seoul A zone) at maximum). When indirect CO2 storage effect is combined in calculation, it turned out that total potential CO2 reduction capacity increases 1.6 times to 1.8 times more by integrated CO2 storage effect by an urban park. Accordingly, it seems to be more effective to increase the planting density and tree size than broadening the size of the park to increase CO2 reduction effect in a city. Moreover, this study identified that a urban park functions to mitigate urban heat island effect, reduce the consumption of building cooling energy and eventually reduce CO2 emission. Therefore, an attentive consideration should be given to the multifaced effects of urban park as city environment controller when it is planned and designed.
This study calculated CO2 storage capacity by target park on the basis of the formulas derived from direct CO2 storage equations that can be applied to a new urban park to come in future. The estimated results showed similar phenomenon in CO2 storage per unit area by park. It was demonstrated that the new equations based on tree height, root diameter and number of tree can be applied to a urban park to be newly built. In addition, The study drew out a formula that can calculate indirect CO2 reduction capacity and applied it to know indirect CO2 reduction effect by park in target areas. The combined effect of direct and indirect CO2 reduction capacity turned out to be 1.6 to 1.8 times greater than direct CO2 reduction capacity alone. Therefore, this result supports the existing studies that suggest urban park is indirectly effective in restraining CO2 emission through the reduction of a building cooling energy consumption. Here, we could test the applicability of indirect potential CO2 reduction capacity equation.
Every species of trees has different growth characteristics, so has different CO2 absorption and storage capacity. However, CO2 storage equations invented in the present study couldn't reflect these points fully. Accordingly, efforts need to come further to calculate CO2 storage capacity by species because each species of trees have different CO2 storage capacity. Futhermore, advancement needs one more step to be taken further over CO2 storage capacity by the shape and type of trees to tree-planting design technique to increase CO2 storage effect of trees to be planted in a park. Moreover, actual amount of energy in use by buildings near a urban park should be examined to analyze indirect CO2 reduction effect by the park more objectively and followed by empirical study on the effect range and extent of temperature reduction by urban park & green spaces. Last, the present study conducted the estimation of CO2 storage capacity at the point of planting trees. Therefore, time-series simulation analysis is also needed in future study.
References
1. | Krihs, Climate change and sustainable land management strategies in korea Ⅲ, (2010). |
2. | D.H Kim, E.G Kim, J.S Yang, H.G Kim, An Econometric Analysis of Mitigating Urban Heat Island Effect with Urban Forest, Journal of the korean forest society, (2011), 100(1), p79-87. |
3. | W.J Kim, E.S Kim, A study on ensuring carbon reservoir and reducing carbon emissions plan, Seoul development institute, (2010), p47-54. |
4. | E.J Park, k.y Kang, Estimation of C Storage and Annual CO2 Uptake by Street Trees in Gyeonggi-do, Journal of the korean society of environmental, (2010), 24(5), p591-600. |
5. | Korea energy economics institute, www.keei.re.kr, (2010). |
6. | M.H Yoon, T.M Ahn, An application of satellite image analysis to visualize the effects of urban green areas on temperature, Journal of the korean institute of landscape architecture, (2009), 37(3), p46-53. |
7. | G.G Lee, Sustainability indicators of greenspace in apartment sites, The graduate school seoul national university, (2003). |
8. | J.H Lee, G.G Lee, J.H H, Development of carbon netural indicator using capacity of carbon storage on urban forest, Journal of korea planners association, (2012), 47(2), p203-213. |
9. | H.D Jeong, Basic research of Daejeon forest sector and the UN Framework Convention on Climate Change, The policy report of daejeon development institute, (2009), p51-63. |
10. | Y.H Cho, H.G Jo, A study on effect of vegetation cover on atmospheric purification in seoul korea, Journal of the korea environment restoration, (2002), 5(4), p51-60. |
11. | H.G Jo, Y.H Yun, K.E Lee, Atmospheric CO2 sequestration by urban greenspace, Journal of the korean institute of landscape architecture, (1995), 23(3), p80-93. |
12. | H.G Jo, T.W Ahn, A study on greenspace planning strategies for thermal comfort and energy savings, Journal of the korean institute of landscape architecture, (2010), 38(3), p23-32. |
13. | H.G Jo, G.E Lee, Energy saving and reduction of atmospheric CO2 concentration by and planning guideline for urban greenspace, Journal of the korean institute of landscape architecture, (2000), 27(5), p38-47. |
14. | H.K Jo, D.h Cho, Annual CO2 Uptake by urban popular landscape tree species, Journal of the korean institute of landscape architecture, (2000), 27(5), p38-47. |
15. | H.G Jo, Y.H Jo, T.W Ahn, Effects of Urban Greenspace on Improving Atmospheric Environment, Journal of the korean institute of landscape architecture, (2003), 31(3), p83-90. |
16. | Land & Housing institute, Study of economic policy application of the planning elements of the green urban of LH, (2011). |
17. | H. A. M Ayman, M. A El-Sayed, Evelopment of sustainableurban green areas in Egyptian new cities : The case of El-Sadat City, Landscape and Urban Planning, (2011), 101, p157-170. |
18. | J. C Daniel, P. D Anderson, G. T Howe, C. A Harrington, J. E Halofsky, D. L Peterson, D. C Shaw, Clair J. B, Forest response to climate change in the northwestern United States, Forest Ecology and Management, (2011), 261, p1121-1142. |
19. | V.T Ca, T Asaeda, E.M Abu, Reduction in air conditioning energy caused by a nearby park, Energy and Building, (1998), 29, p83-92. |
20. | S Dimas, S Gavriel, The Economics of Ecosystem and Biodiversity, (2008). |
21. | D. H Donovan, D. T Butry, The value of shade : Estimating the effect of urban trees on summertime electricity use, Energy and Building, (2009), 41, p662-668.![]() |
22. | IPCC, Land Use, Land-Use Change and Forestry, A Special Report of the IPCC, Cambridge University Press, (2000), 377. |
23. | E Laitat, T Karjalainen, D Loustau, M Lindner, Contribution of forests and forestry to mitigate greenhouse effects, Bio-technology, Agronomy Society and Environment, (2000), 4(4), p241-251. |
24. | M Mchale, E.G Mcpherson, I. C Burke, The potential of urban tree planning to be cost effective in crbon credit markets, Urban Forestry and Urban Greening, (2007), 6, p49-60. |
25. | E. G Mcpherson, R.A Rowntree, Energy conservation potential of urban tree planting, Journal of Arbotriculture, (1993), 19, p321-331. |
26. | E. G Mcpherson, J.R Simpson, Q Xiao, C Wu, Los Angeles One Million Tree Canopy Cover Asswssment-Final Report : Pacific Southwest Research Station, USDA Forest Service, Albany, CA, (2007), p48. |
27. | J Moore, Carbon Sequestration Potential of the Million Trees NYC Initiative, http://snrecmitigation.wordpress.com/2009/04/22/Carbon–sequestrationpotential-of-the-million-treesnyc-initiative/, (2009). |
28. | D. J Nowak, D. E Crane, Carbon storage and sequestration by urban trees in the USA, Environmental Pollution, (2003), 116, p381-389.![]() |
29. | R. A Rowntree, D. J Nowak, Quantifying the role of urban forests in removing atmospheric carbon dioxide, Journal of Arboriculture, 17(10), p269-275. |
30. | J. R Simson, Improved estimates of tree-shade effects on residential energy use, Energy and Building, (2002), 34, p1067-1076. |
31. | H,B. L Turner, E. F Lambin, A Reenberg, Land change science special feature the emergence of land change science for global environmental change and sustainability, Proceedings of the National academy of Science, (2007), 104(52), p20666-20671. |
32. | R. T Watson, I. R Novel, B Bolin, N. H Ravindranath, D.J Verado, D. J Dokken, Land use, Land-use change, and Forestry, Cambridge University Press, (2000), 377. |