KIEAE Journal
[ Article ]
Journal of the Korea Institute of Ecological Architecture and Environment - Vol. 13, No. 5, pp.31-42
ISSN: 2288-968X (Print) 2288-9698 (Online)
Print publication date Oct 2013
Received 26 Sep 2013 Revised 17 Oct 2013 Accepted 28 Oct 2013
DOI: https://doi.org/10.12813/kieae.2013.13.5.031

A Study on the Improvement of G-SEED through Analysis of the Previous Studies

YunYo Sun* ; RyuSoo Hoon**
*Dept. of Architecture Kongju National Univ. South Korea **Corresponding author, Dept. of Architecture Kongju National Univ. South Korea
선행연구 분석을 통한 녹색건축 인증제의 개선방향에 관한 연구

Green Standard for Energy and Environmental Design (G-SEED) is evaluates the eco-friendliness of the building as an abjective means. Study in green building is made actively, and is being developed through constant revision. However, study results of green building have not been fully reflected in the standard.

Therefore, this study analyzes the previous studies about G-SEED and checks the reflection of requirements. This study will be a reference of future revision of G-SEED.

Score of items are divided into low and high score items. These items should be reflected appropriately in the standard through the score adjustment. Some requirements proposed in previous studies was reflected, while substantial requirements was not reflected. Proposed improvement requirements are classed as to establish specific standards, strengthen standards, propose a new evaluation method to existing items, and add new items.

Keywords:

Green Standard for Energy and Environmental Design, Previous Studies, Apartment Houses, 녹색건축인증, 선행연구, 공동주택

1.서 론

1.1.연구 배경 및 목적

친환경건축물(Green Building)이란, 에너지 절약과 환경 보전을 목표로 에너지 부하저감, 고효율 에너지설비, 자원재활용, 환경공해 저감기술 등을 적용하여 자연친화적으로 설계, 건설하고 유지관리한 후, 건물의 수명이 끝나 해체될 때까지도 환경에 대한 피해가 최소화되도록 계획된 건물1)을 의미한다.

1992년 브라질 리우에서의 UN 기후변화 협약 이후 전 세계적으로 기후변화 및 지구환경에 대한 관심이 높아지면서, 건설을 포함한 모든 산업분야에서 온실가스 감축을 위한 노력을 기울이고 있다. 이에 따라 각 국가들은 녹색 건축물에 대한 인증 제도를 마련하여 운영하고 있다.

또한 국내에서도 저탄소 녹색성장 기본법2)에 따라 자원절약형이고 자연친화적인 건축물의 건축을 활성화하기 위해 2002년부터 녹색건축 인증3)이 시행되고 있다. 이러한 인증제도는 건축물의 친환경성을 평가하는 객관적인 수단이며, 앞으로 녹색 건축물이 나아가야 할 방향을 제시하는 역할을 한다.

녹색건축 인증제는 2002년부터 공동주택에 대한 친환경건축물 인증4)기준을 시작으로, 현재 몇 차례의 개정을 거쳐 공동주택, 복합건축물(주거), 업무용 건축물, 학교시설, 판매시설, 숙박시설, 소형주택, 기존공동주택, 기존 업무용 건축물, 그 밖의 건축물, 복합건축물에 대한 인증이 시행 되고 있다. 인증제가 시행됨에 따라 녹색건축 인증제에 대한 연구가 활발히 이루어지고 있으며, 개정을 통해 발전되고 있다. 하지만 인증제에 대한 연구 결과가 개정된 인증제에 충분히 반영되지 못하고 있다.

이에 본 연구는 기존 녹색건축 인증제에 대한 선행연구를 분석하여, 연구에서 제시된 문제점 및 개선점에 대해 개정된 녹색건축인증제에서의 반영정도를 확인한다. 또한 이를 바탕으로 향후 국내 녹색건축인증제의 개선방향성의 참고자료로 활용하고자 한다.

1.2.연구 내용 및 범위

본 연구의 내용은 인증제에 대한 선행연구 분석을 통하여, 평가 항목별 점수획득에 관한 연구를 분석하고, 항목에 대한 문제점 및 개선 요구사항을 확인한다. 그리고 개정된 인증 기준 비교를 통해 개선 요구사항의 반영정도를 분석한다.

선행 연구의 범위는 2002년에서 2012년까지 국내 학술지에 발표된 녹색건축물 인증에 관한 논문 및 기사를 선행연구의 범위로 설정하며, 건물의 용도는 가장 연구가 활발히 진행되고 있는 공동주택을 대상으로 한다. 또한 개정된 녹색건축 인증제에 대한 기준은 2013년 6월에 개정된 인증기준을 의미한다.

Fig. 1.

Research Flowchart


2.녹색건축 인증제

2.1.녹색건축 인증제 개요

녹색건축 인증제는 2002년부터 공동주택에 대한 인증을 시작으로 현재 공동주택, 복합건축물(주거), 업무용 건축물, 학교시설, 판매시설, 숙박시설, 소형주택, 기존공동주택, 기존 업무용 건축물, 그 밖의 건축물, 복합건축물에 대한 인증이 시행되고 있다. (Table 1 참조5))

G-SEED Outline

2013년 2월 ‘녹색건축물 조성지원법’을 개정·시행하면서 ‘친환경 건축물 인증제(건축법)’와 ‘주택성능등급 인정제(주택법)’가 통합되어 ‘녹색건축 인증제’로 개정되었다. 또한 인증제의 브랜드 강화를 위해 영문명칭(G-SEED6))을 반영하였다.

녹색건축 인증제로 개정되면서 인증기관은 종전 4개 기관에서 11개 기관으로 확대되었으며, 평가항목은 종전 9개 분야에서 유사 분류항목을 통합하여 7개 분야로 분류체계가 재정립 되었다.

2.2.녹색건축 인증제 개정 전·후 비교

공동주택 부문은 2002년 시행 이래로 2006년, 2010년, 2012년, 2013년 4차례 개정되었다. (Table 2 참조) 2006년 개정시에는 5개 부문(추가항목 포함)의 평가항목이 세분화되어 9개 평가항목으로 구분되었고, 평가 및 가산항목 합계점수가 136점으로 상향 조정되었다.

G-SEED Revision Contents

2010년 개정시에는 평가항목, 평가방법, 배점기준이 조정됨에 따라 필수항목이 추가되었고, 인증등급 산정시 가중치를 부여하고 인증등급이 2등급에서 4등급으로 확대되었다.

2012년 개정시에는 공동주택의 친환경건축물 및 주택성능등급 평가기준이 일원화되어 주택성능등급인정제 항목이 대부분 유지관리 부문으로 삽입되었으나 2013년 개정시 주택성능분야는 부문으로 분리되었다. 공동주택 인증 평가항목 중 녹색건축 심사요소에 부합하지 않는 주택성능분야(11개 항목)은 인증 평가시 성능등급서에만 표시하고 인증평가를 위한 배점을 부여하지 않으며, 성능등급은 공동주택의 입주자 모집공고시 공동주택 인증심사기준에 따라 평가하여 단지별 최소등급을 ★에서 ★★★★로 표시하도록 개정되었다.


3.녹색건축 인증제 평가 항목별 점수획득

평가 항목별 특징에 따라서 Table 3과 같이 점수 획득이 어려운 저득점 항목과, 점수획득이 비교적 쉬운 고득점 항목으로 분류 할 수 있었다. 이는 사례평가와 득점분석을 한 선행 연구의 결과 이다. (2006년 인증기준)

Obtained Score of Item

3.1.저득점 항목

점수획득이 어려운 저득점 항목에는 토지이용 및 교통 부문에서 기존자연자원 보존율, 외부보행자 전용도로 네트워크 연계여부 항목 등이 있었다.

기존 자연자원 보존율 항목은 2010년 개정시 삭제되었으며, 외부보행자 전용도로 네트워크 연계여부 항목은 점수가 상향 조정('10년 개정)되었고, 인정 범위가 확대되었다. 또한 2012년 개정시에는 산출기준이 보다 구체화 되었다.

재료 및 자원 부문에서는 생활용 가구재 사용억제 대책의 타당성, 기존 건축물의 주요구조부 재사용으로 재료 및 자원의 절약, 기존 건축물의 비내력벽 재사용으로 재료 및 자원의 절약 항목이 있었다. 생활용 가구재 사용억제 대책의 타당성 항목은 2010년 개정시 점수가 상향조정 되었다. 기존 건축물의 재사용에 관한 항목은 2006년 신설되었으며, 리모델링시에만 평가하는 항목이기 때문에 점수획득이 어려운 것으로 판단된다.

물순환관리 부문에서는 우수이용, 중수도 설치 항목이 있었으며 중수도 설치 항목은 가장 많은 선행연구에서 점수획득이 어려운 항목이었다. 2010년 개정시 점수가 하향조정 되었고, 가산항목에서 평가항목으로 개정되었다. 또한 수도법 시행규칙에서 규정하는 의무시설의 경우 +2%를 만족할 경우 배점을 부여한다는 부분이 추가 되었다.

유지관리 부문의 항목은 저득점 항목 보다는 고득점 항목이라는 결과가 많았던 반면, 생태환경 부문의 항목은 저득점 항목이라는 결과가 많았다. 생태환경 부문에서는 연계된 녹지축 조성, 비오톱 조성, 표토재활용 항목 등이 있었으며 이중 표토재활용 항목은 2010년 개정시 삭제되었다.

3.2.고득점 항목

점수 획득이 비교적 쉬운 고득점 항목에는 토지이용 및 교통부문에서 체계적 상위계획 수립 여부, 초고속 정보통신 설비의 수준, 도시 중심 및 지역중심과 단지 중심 간의 거리 항목 등이 있었다.

체계적 상위계획 수립 여부 항목과 초고속 정보통신 설비의 수준 항목은 2010년 개정시 삭제되었는데, 변별력이 떨어져 점수 획득이 쉬운 항목이었기 때문인 것으로 판단된다. 하지만 도시 중심 및 지역중심과 단지 중심간의 거리 항목은 산출기준의 구분만 개정되었다.

재료 및 자원 부문에서는 유효자원 재활용을 위한 친환경인증제품 사용여부 항목 등이 있었다. 친환경 인증제품의 사용수로 평가하던 방법에서 2010년 개정시 주된 건축물에 사용하는 것과, 외부공간에 사용하는 것에 가중치를 두어 산출기준을 강화하였으며 필수항목으로 개정되었다. 또한 2012년 개정시에는 두 부분 모두에서 사용한 경우에 점수를 획득할 수 있도록 기준이 강화되었다.

물순환관리 부문에서는 생활용 상수 절감 대책의 타당성 항목이 있었다. 이 항목은 2002년 기준 건물 대비 심사 대상 건물의 일일 1인당 상수 사용량 절감율에 따른 평가에서 2006년 환경표지 인증을 얻은 제품의 적용여부에 따라 평가하는 방법으로 개정되었으며, 2010년 개정시 필수항목으로 개정되었다.

유지관리 부문은 환경을 고려한 현장관리계획의 합리성, 운영/유지관리 문서 및 지침 제공의 타당성, 사용자 매뉴얼 제공 항목모두가 고득점 항목이었다. 환경을 고려한 현장관리계획의 합리성 항목은 크게 개정된 것이 없었고, 운영/유지관리 문서 및 지침 제공의 타당성 항목은 2010년 개정시 필수항목으로 개정되고, 배점은 3점에서 2점으로 감소하였지만, 1급을 받기위한 항목 수는 5항목 이상에서 7항목 이상으로 강화되었다. 2012년 개정시에는 8항목 이상으로 상향 조정되었으며, 최소평점도 1.0점에서 1.2점으로 강화되었다. 또한 사용자매뉴얼 제공 항목은 2010년 개정시 3점에서 1점으로 점수가 하향 조정되었고, 1급을 받기위한 항목 수는 4항목 이상에서 5항목 이상으로 개정되었다. 그리고 2012년 개정시 6항목 이상 채택으로 강화되었다. 유지관리 부문은 변별력이 떨어져 점수획득이 쉽기 때문에 필수항목으로 설정하거나 배점을 하향조정하고 기준을 강화한 것이라고 판단된다.

실내환경 부문에서는 각종 유해물질 저함유 자재의 사용, 각 실별 자동 온도조절 장치 채택여부 항목 등이 있었다. 각종 유해물질 저함유 자재의 사용 항목은 2010년 개정시 실내공기 오염물질 저방출 자재의 사용으로 바뀌었고, 필수항목으로 개정되었다. 또한 산출기준에 가구용 자재까지 포함되어 기준이 강화되었다. 2012년 개정시에는 최소평점 4점에서 4.8점으로 상향조정되었다. 각 실별 자동 온도조절 장치 채택여부 항목은 크게 개정된 것이 없었다.

3.3.소 결

사례평가와 득점분석을 한 선행 연구의 결과는 평가항목별 특징에 따라 점수 획득이 어려운 저득점 항목과, 획득 점수가 높은 고득점 항목으로 구분 할 수 있었다. 저득점 항목의 경우 항목삭제, 점수의 상향조정, 산출기준의 구체화 등으로 개정되었으며 고득점 항목의 경우 항목삭제, 점수의 하향조정, 기준 강화 등으로 개정되었다.


4.녹색건축 인증제 평가 항목별 문제점·개선 요구사항 및 반영여부

4.1.토지이용 및 교통

토지이용 및 교통 부문은 2013년 현재 12개 항목으로 구성되어 있으며, 항목별 총점은 18점, 가중치는 15로 2002년과 대비해 토지이용 및 교통의 평가 부문은 감소하였으나, 2010년 이후로는 항목 및 비율의 큰 변동이 없다.

‘기존 대지의 생태학적 가치’항목은 기존 대지의 생태학적 보존 여부를 판단할 수 있는 구체적인 언급이 필요[참고문헌 27 ; 이하 번호]하다는 개선 요구사항이 있었다. 2010년 개정시 ‘택지개발지구 등 대규모 개발 사업지구, 해안 및 습지 매립지 등은 생태학적 가치가 낮은 대지에 해당하지 않음’으로 구체적으로 언급이 되었다.

‘기존 자연자원 보존율’ 항목은 시공시 현장에서의 변수 발생에 따라 계획이 변경되거나, 단지의 입지환경에 따라 적용가능 여부가 다르나, 보호가치가 높은 현장일수도 있다는 문제점이 있었으며, 이에 대한 개선방안으로는 2010년 개정시 삭제되었지만, 기존의 자연파괴를 최소화하기 위해서는 평가항목의 유지가 필요하다[3]는 요구사항이 있었다. 하지만 2010년 삭제 이후 신설되지 않았다.

‘일조권 간섭방지 대책의 타당성’항목은 기존의 건축물 뿐 아니라 장래의 인접대지 건축물에 미칠 영향에 대해서도 고려해야 하므로 인접대지 조건에 대한 평가기준을 제시[27]해야 한다는 요구사항은 반영되지 않았다.

‘커뮤니티 센터 및 시설공간의 조성수준’항목은 2012년 개정시 커뮤니티 센터 및 시설계획 여부 항목에서 명칭이 변경되었다. 2010년 개정시 세대수에 따른 커뮤니티 센터의 최소면적과 독립된 출입구 및 부대시설(화장실)의 확보에 대한 기준은 마련되었으나, 커뮤니티센터 내 적용되는 공간에 대한 구체적인 기준이 없다[3]는 문제점이 있었고, 이에 대해 제도적으로 평가기준에서 커뮤니티 센터에 적용될 수 있는 공간의 종류 및 크기와 같은 구체적인내용 추가에 대한 요구[32327]가 있었다. 이는 2012년 개정시 반영되어 커뮤니티 공간면적 및 종류에 대한 기준이 추가되었고, 주민공동시설에 대한 설치 기준이 추가 되었다. 또한 양적 평가보다는 질적 평가가 우선되어야한다[23]는 요구사항이 있었지만, 여전히 면적에 대한 기준으로 커뮤니티 센터 및 시설·공간계획 여부로 산출된다.

Land Use and Transportation

Land Use and Transportation

‘단지 내 자전거 보관소 및 자전거도로 설치여부’ 항목은 평가시 자전거보관소의 규모로 평가하고 있으며, 위치에 대한 기준은 ‘주동의 필로티 및 출입구 인접배치’ 외에 없다는 문제점[3]이 있으며, 이에 개선 요구사항은 평가기준에서 자전거보관소 규모 계산시 각 단지의 거주자특성을 고려한 규모 산정이 필요하며, 자전거 보관소 설치 위치와 관련하여 실용성과 거주자의 편의를 고려한 구체적인 산출기준 마련이 요구[3]가 있었지만, 산출기준만 강화되었을 뿐 거주자의 특성을 고려한 규모 산정에 대한 부분은 반영되지 않았다.

또한 적절한 보차분리가 필요[29]하다는 요구사항은 2010년 개정시 산출기준에 보행자도로와의 분리조치가 이루어져야한다는 부분이 추가 되었지만, 단지외부와의 연계도 필요[29]하다는 요구사항은 반영되지 않았다. 2010년 개정시 산출기준에 언급이 되었지만 단지 출입구에서 자전거 보관소까지의 기준을 평가하는 내용이었다.

이 외에도 대중교통 체계 확립 및 접근성재고, 적정밀도 개발 및 기반시설 확보, 부지 선택 및 보존, 보행자 네트워크 형성, 범죄와 재해에서 안전한 환경 조성의 새로운 평가기준을 제시[2]하는 연구가 있었지만 반영되지 않았다. 또한 공간 접근성 문제에서 시뮬레이션을 통한 단지에서 이동 거리 및 접근이 양호한 위치를 선정하는 등의 평가기준을 제시[8], 공사 중에 발생되는 외부환경 영향을 최소화하기 위한 노력 필요[22], 토지의 재이용을 통한 기존 생태상의 전개 최소화[25], 구체적인 토지이용 관리계획과 교통통로 공간 조성 방안요구[25], 열섬효과 및 빛 오염물질 항목 추가 및 보완[32]의 요구사항이 있었지만 반영되지 않았다.

4.2.에너지 및 환경오염방지

에너지 및 환경오염방지 부문은 2006년에서 2012년 개정시까지 에너지 부문과 환경오염 부문이 분리가 되어 있었지만, 2013년 개정시 에너지 및 환경오염 부문으로 통합되었다. 항목은 4개로 다른 부문에 비해 적지만, 점수는 총점 21점, 가중치 25로 가장 높다.

1) 에너지 성능

‘에너지 성능’ 항목은 2013년 현재 에너지성능지표검토서와 건축물 에너지효율등급 산출결과 중에서 유리한 점수로 적용하며, 배점은 12점으로 인증제 항목 중 가장 높은 점수 비율을 차지하고 있다. 에너지 절약에 대한 높은 관심에 따라 많은 연구가 이루어지고 있었으며, 또한 국외 인증제도인 ‘LEED’나 ‘CASBEE’의 에너지 평가방법을 도입하거나 비교한 연구[9173640]가 많이 있었다.

EPI7) 산정 시 열관류율을 산정하여 평가하고 있지만, 냉난방부하까지 산출하여야한다[5]는 요구사항은 반영되지 않았다. 또한 열관류율만으로는 에너지 사용량이 어느 정도 될 것인지 판단하기 어렵지만 CASBEE처럼 건물의 냉난방부하를 평가한다면 보다 효율적일 것[12]이라는 요구사항은 반영되지 않았다.

필수항목으로 정해졌지만('10) EPI 평점평균 합계에서 저조한 점수를 받아도 최소기준이 만족하도록 되어 있어 이는 건물의 에너지 절약기준으로 미약하다는 문제점에 따라 실질적인 에너지효율성을 높이기 위해서는 평가기준을 강화할 필요가 있다[9]는 요구사항이 있었지만, 이 역시 반영되지 않고 2012년 개정시 EPI 평점합계의 평균점수 구분만 1-7급에서 1-4급으로 개정되었다.

전체 건물에너지 시뮬레이션을 통한 소비량 기준 필요[17], EPI에 따른 단위면적당 소비량을 참고하는 방법과 더불어 LEED와 같이 전체 건물의 에너지 시뮬레이션을 통한 에너지 소비량을 분석하는 요구[17]가 있었지만 반영되지 않았다.

적정 창면적과 고효율 창호 사용에 따른 건물에너지 절감율 증가를 고려하여 건물 개구부기준을 강화해야한다는 요구[17]는 건축물의 에너지절약 설계기준 개정('13)됨에 따라 복층유리 수준의 창호에서 로이복층유리 수준으로 강화되었다.

EPI의 경우 개별평가방식을 통하여 에너지 성능을 평가하고 있어, 에너지 절약기술이 평가항목에 포함되지 않아 점수는 반영되지 않고 단순 평가가 어려운 복잡한 기술에 의한 에너지 절약 정도를 평가할 수 없다는 한계에 따라 총량평가방식8)을 함께 할 수 있도록 개선이 필요[24]하다는 요구가 있었지만 반영되지 않았다.

에너지 소비량 항목은 하나의 항목으로 되어 있기 때문에 세부적인 평가항목 및 구체적인 사항이 포함[353640]되어야 한다는 연구가 있었지만, 에너지에 대한 부분은 EPI 및 건축물 에너지 효율등급에 따라 평가됨에 따라 단일 항목을 유지하고 있다.

CASBEE처럼 에너지 전 과정을 평가[36]하거나, EPI에 의한 평가가 아닌 에너지 사용량에 의한 평가방법 도입[40]이 필요하다는 요구사항이 있었지만 반영되지 않았다.

에너지 분야에 대해 강행규범으로 고려가 필요하다는 요구는 2010년 개정시 필수항목으로 개정됨에 따라 반영된 것으로 판단된다.

이처럼 ‘에너지성능’ 항목에 대한 여러 문제점 및 개선 요구사항이 있었지만 대체로 개정시 반영되지 않았으며, 에너지 절약에 대한 부분이 점점 중요해짐에 따라 앞으로 개정되는 인증제에서는 좀 더 선행연구의 내용이 반영되어야 할 것이다.

Energy and Prevention of Environmental pollution

2) 신·재생에너지 이용

‘신·재생에너지 이용’항목은 ‘대체에너지 이용’ 항목에서 2010년 개정시 명칭이 변경되었다. 이 항목은 대체에너지 시설의 설치여부 만으로도 평가점수 획득이 가능('06)하여, 최소기준만 적용되고 있다는 문제점[3]에 2010년 개정시 난방, 냉방, 전기설비용량 또는 급탕부하 합이(5~1%) 이상을 담당하는 수준의 시설을 설치한 경우 점수를 획득할 수 있도록 평가기준이 강화[33]되었으나, 비율 상향조정이 필요하다는 요구사항[3]이 있었다. 하지만 2012년 개정시 산출기준의 구분만 1-4급으로 개정되었으며, 비율이 상향조정 되거나 평가기준이 강화되지 않았다.

3) 이산화탄소 배출저감

‘이산화탄소 배출저감’항목은 2013년 개정시 환경오염방지 부문에서 에너지 및 환경오염 방지 부문으로 통합되었다. 난방부하의 20% 이상을 열병합발전의 배열을 이용하거나 사용 에너지원 및 이에 따른 이산화탄소 배출량을 산정하여 평가하였지만, 2010년 개정시 이산화탄소 배출을 저감시킬 수 있는 시스템의 적용여부를 평가하는 방법으로 변경되었다.

건물 운영 및 유지관리 단계가 전체 라이프사이클 중 온실가스 배출에 가장 많은 비중을 차지하고 있음을 고려하여 시스템의 수명을 고려한 기준을 제시[9] 하고, 라이프사이클을 고려하여 에너지 소비를 평가가 필요[9]하다는 요구사항이 있었지만 반영되지 않았다.

또한 이산화탄소에 의한 환경오염의 심각성에 대한 교육이 필요[33]하며, 단지와 세대 내에서 열병합 발전 시스템을 통한 자가 발전으로, 냉·난방시 발생하는 열로 인한 이산화탄소의 배출량을 줄이는 방안을 강구[33]해야 한다는 요구사항이 있었지만 이러한 부분은 평가항목에 반영되지 않았다.

4)환경오염방지

환경오염방지에 대한 다른 요구사항으로는 CASBEE처럼 건물 전생애기준 LCCO2 산출이 필요[5], 건축물로 인해 발생되는 환경오염에 대한 추가적인 고려 필요[7], 환경오염 부문의 점수 확대 또는 평가항목의 세분화[35]와 같은 의견이 있었지만 반영되지 않았다.

4.3.재료 및 자원

재료 및 자원 부문은 6개 항목과 리모델링시에만 평가하는 2개 가산항목 구성되어 있다.

‘재활용 생활폐기물 분리수거’항목은 보관시설계획에 대한 구체적인 추가설명이 필요[27]하다는 요구가 있었다. 2010년 개정시 재활용 생활폐기물 보관시설과 분리수거용기의 설치에 대한 기존 규정보다 구체적인 규정이 마련되었지만, 이보다 실제 공동주택 단지에서의 현실적인 분리수거 방법을 고려한 평가방법으로 전면적인 개정이 필요[3]하다는 요구사항이 있었다. 하지만 2012년 개정시 반영되지 않았다.

‘음식물 쓰레기 저감’항목은 인증 평가시 음식물 쓰레기 전용수거를 위한 공간의 설치만으로 평가하도록 되어있어 음식물 쓰레기 전용수거공간이나 수거용기에 대한 구체적인 기준이 없다는 문제점[3]이 있었다. 하지만 2012년 개정시 산출기준 등급 및 내용에 관한 개정만 있었으며, 위치 등에 관한 기준은 반영되지 않았다.

Material and Resources

그 밖에 기존 자재의 재활용 여부도 함께 평가[5], 재사용, 재활용 자재의 사용[41]에 대한 요구사항이 있었지만 재활용에 대해서는 리모델링시 평가하는 항목에만 반영될 뿐, 평가항목에서는 반영되지 않았다. 또한 지속가능한 구매환경관리 방안, 재활용 가능한 폐기물의 효율적인 관리 방안, 자원 성능 측정과 모니터링[25] 요구, 자재의 재이용, 공인된 목재의 이용 항목 등 재활용 부분에 관한 항목에 대한 고려가 필요[32]하다는 요구사항이 있었지만 반영되지 않았다.

또한 기존의 평가범주를 바꾸어 ‘건물의 안전 및 장수명화’, ‘건물의 형상’으로 새로운 항목을 추가하거나 이동하는 제안[41], ‘부하 자원의 절약’, ‘다양성·가변성’으로 변경하는 제안[42]이 있었지만 반영되지 않았다.

4.4.물순환 관리

물순환 관리 부문은 4개 항목으로 구성되어 있으며, 2013년 개정시 수자원에서 물순환관리로 변경되었다. 2002년부터 평가항목은 4개로 동일하며, 개정될 때 항목별 배점이 약간씩 차이를 보였다.

‘우수부하 절감대책의 타당성’항목은 평가기준에 제시되어있지 않은 인공지반에 대한 산출기준을 제시가 필요[27]하다는 요구사항이 있었지만 반영되지 않았고, 수자원 활용측면에서 투수성 포장면의 설치, 투수성 포장시설이 미흡하게 나타나는 문제점에 따라 전반적인 개선이 요구[33]되었다. 평가방법이 투수성 포장 면적 산출하는 방법에서 우수유출 저감시설의 연계면적 비율로 평가(2010년 이후)하는 방법으로 개정되었으므로 반영되었다고 판단된다.

‘우수이용’항목은 2010년 개정시 우수사용량을 산출기준으로 하던 것에서 우수저수조 용량의 평가로 개정되었지만 우수 이용을 위한 시설에 대한 기준이 없어 평가기준에서 우수저수조 용량의 평가 외에도 실제 이용할 수 있도록 여과장치 및 송수시설 등이 제대로 적용되었는지에 대한 평가가 필요[3]하다는 요구사항이 있었지만, 2012년 개정시 산출기준의 등급의 변화만 있을 뿐 반영되지 않았다.

Water Management

‘중수도 설치’항목은 공동주택에 적용되는 중수도시설의 친환경 효과에 대한 실효성을 기준으로 평가항목의 필요성에 대한 재검토가 필요[3]하다는 요구가 있었다. 하지만 중수도 설치 항목은 2010년 개정시 가산항목(4점)에서 평가항목(3점)으로 개정되었지만, 산출기준은 개정되지 않았다.

4.5.유지관리

유지관리 부문은 2013년 현재 5개 항목으로 구성되어 있으며, 이 중 수리용이성 항목은 2012년 개정시 추가되었다.

‘운영/유지관리 문서 및 지침 제공의 타당성’ 항목은 2010년 개정시 평가항목에서 필수항목으로 개정되었으며, 평가 기준이 강화되었다. 하지만 친환경인증과 관련된 정보의 부족으로 친환경요소의 관리가 적절히 이루어지지 못한다는 문제[3]에 친환경인증에 대한 내용을 필수로 포함할 필요가 있다는 요구사항[3]이 있었지만 산출기준에서 지침 제공 항목에 친환경인증에 대한 내용은 없었다.

2012년 개정시 친환경건축물인증제도와 주택성능등급이 통합되면서 유지관리에 대한 비중이 에너지부문보다 2배정도 높아진다는 문제점[13]이 있었다. 그러나 2013년 개정시 사회적 약자의 배려, 홈네트워크, 방범안전, 화재소방, 파난안전 항목이 주택성능분야 부문으로 이동하면서 유지관리 항목의 배점에 대한 문제점이 개선되었다.

평가항목이 보충이 필요[5]하다는 요구사항에 대해서는 2012년 개정시 수리용이성에 전용부분, 공용부분 2개 항목이 추가되었다. 그러나 체계적인 관리시스템 및 프로그램 필요[33], 건물 커미셔닝 의무화[1125], 모니터링에 의한 실제 데이터 측정 및 확인[1125], 최적 환경성능을 위한 피드백 시스템 필요[1125], 경제성 항목을 추가하여 생애주기 비용, 시공비용, 유지관리 비용 평가[40]에 대한 요구사항 및 제안이 있었지만 이는 반영되지 않았다.

4.6.생태환경

생태환경 부문은 현재 4개 항목으로 구성 되어 있으며, 2010년 개정시 항목 변경(6개→4개) 및 기준에 대한 변경이 이루어졌고 이후의 개정에서는 큰 개정사항이 없었다.

‘연계된 녹지축 조성’ 항목은 단지내부 연속된 녹지축은 면적 가중치 평가로 변경[14]해야 한다는 요구사항이 있었지만, 개정이후에도 여전히 녹지축 길이와 대지 외곽길이의 합과 비율에 대한 가중치로 평가하고 있다. 또한 단지 외부 녹지와의 연계성은 길이 가중치로 평가로 변경[14]해야 한다는 요구사항도 개정되지 않았다. 생태통로로 인정되는 범위 및 연계성 평가기준에 대한 구체적인 언급이 필요[27]하다는 요구사항에 대해서는 2010년 개정시 단지외부 녹지와의 연계성 정도구분에서 생태통로에 대한 언급을 삭제하였다.

‘녹지공간률’ 항목은 2010년 개정시 삭제되었으나 자연지반녹지율, 생태면적률 항목에서 녹지에 대한 부분을 평가하고 있었다. 단지 내 녹지공간률 뿐만 아니라 주변 경관녹지의 입면면적을 연계한 평가기준이 필요[34]하다는 요구사항은 개정 이후에도 주변 경관녹지에 대한 평가보다는 외부공간 및 건물 외피의 면적을 평가하는 생태면적률 항목을 보았을 때 이는 반영되었다고 보기가 어렵다.

‘인공 환경 녹화기법 적용여부’ 항목은 관리자에게 친환경요소의 적절한 유지관리 방법에 대한 정보가 제공되지 않으며 계획 및 시공시 거주 중에 발생할 수 있는 이용 및 유지관리 문제에 대한 고려가 부족하다는 문제점이 있었다.

Maintenance

Ecological Environment

이의 개선방안으로 친환경요소의 지속성 향상을 위한 유지관리 계획이 필요[3], 조경시설의 유지관리에 대한 매뉴얼 개발 및 제공과 교육이 필요[3]하다는 요구가 있었지만 생태환경의 유지관리 부분은 반영되지 않았다. 생태면적율 공간유형과 동일항목은 생태면적률 가중치에 의한 평가로 통합[14]되어야 한다는 요구사항은 2010년 생태면적률 항목이 신설됨으로 어느 정도 반영되었다고 볼 수 있다.

‘비오톱 조성’항목은 수생비오톱 조성 항목과 육생비오톱 조성 항목이 결합되어 비오톱 조성이라는 항목으로 변경되면서 평가기준이 상향[14]되고, 생물종, 연계, 유지관리 항목이 추가[14]됨으로 비오톱 조성 요구사항이 반영되었지만 사후관리가 필요[3]하다는 부분은 반영되지 않았다('10).

‘표토 재활용율’ 항목은 평가배점 상향 및 타단지 타지역 순환 활용도 인정[14]해야 한다는 요구사항이 있었지만 2010년 개정시 삭제되었다.

또한 생태환경 부문에 대해서는 전체에서 차지하는 비중이 크고 총점에 많은 영향을 미치므로 생태환경 부분에 대한 보완이 필요[29]하다는 요구사항이 있었다. 2006년 13%(6개항목, 18점)를 차지했었지만, 2010년 개정시 가중치가 10%(4개 항목 18점)으로 변경되어 생태환경 부문이 전체에서 차지하는 비중이 감소하였다고 볼 수 있다.

4.7.실내환경

실내환경 부문은 공기, 온열, 음, 빛환경에 대한 10개 항목으로 구성되어 있으며, 2010년과 2011년 개정시 몇 개 항목이 추가되었다. 또한 항목 총점은 28점, 가중치 20으로 에너지 및 환경오염 부문 다음으로 높다.

‘휘발성 유기물질 저방출 자재의 사용’ 항목은 유해물질 저함유 자재의 사용(`06), 실내공기오염물질 저방출 자재의 사용(`10)항목으로 개정되었다. 이 항목은 평가기준이 모호하여 마감재가 적용되는 부위로 나누어 평가하여 마감재에 따라 점수를 획득하되 100% 사용하는 경우에만 배점을 획득할 수 있게 조정이 필요[21]하다는 요구가 있었다. 2010년 개정시 유해물질 저방출 자재는 해당부의 표면적의 최소 70% 이상 적용할 때 점수를 획득 할 수 있는 것으로 기준이 강화되었지만, 100% 사용하는 경우에는 미치지 못했다.

개정된 기준은 적용부위 및 자재에 따라 평가하며, 유해화학물질 방출량이 환경표지인증 획득기준 또는 그에 준하는 기준에 적합한 경우에 대하여 평가하고 있다. 이는 적용범위를 구체화하고 배점 기준을 엄격하게 규정할 필요[31]가 있다는 요구사항을 다소 반영한 것으로 판단된다.

‘건축자재로부터 배출되는 그 밖에 유해물질 억제’항목과 ‘실내 자동온도 조절장치 체택여부’ 항목은 기준에 준하는 결과증명을 시뮬레이션으로 보여줄 것을 제안[1]하는 요구가 있었지만, 건축자재로부터 배출되는 그 밖에 유해물질 억제 항목은 2013년 개정시 삭제되었고, 실내 자동온도 조절장치 채택 여부 항목은 크게 개정되지 않았다.

‘자연환기성능 확보여부’항목은 2011년 개정시 ‘자연통풍 확보 여부’항목으로 변경되었으며 기준이 강화되었다. 또한 ‘단위세대 환기성능 확보여부’ 항목이 추가 되었으며 환기 횟수 및 환기설비 설치여부에 따라 평가한다. 이는 자연환기성능을 단순한 면적 비율이 아닌 법정 자연환기 횟수를 만족시키는 평가기준 마련이 필요[8]하다는 제안이 반영 되었다고 판단된다. 자연환기 부문에서 공간의 깊이를 고려한 항목과, 시뮬레이션을 통한 환기의 결과를 요구하는 항목을 추가해야한다는 요구사항이 있었지만 반영되지 않았다.

Indoor Environment

‘세대 내 일조확보율’ 항목은 6시간동안 최소 2시간의 연속일조를 받는 세대율(%)평가에서 2011년 개정시 채광창 면적 및 인동간격에 따른 방위별 가중치를 계산하는 방법으로 개정되었다. 일조를 받는 세대율 평가와 동시에 최적의 일조율을 위한 고려와 창을 통한 시각 환경 확보가 동시에 이루어질 수 있는 요소가 개선[38]되어야 한다는 제안이 있었지만, 개정된 내용은 세대율 평가에서 채광률을 평가하는 방법으로 개정되었기 때문에 반영되었다고 보기 어렵다.

그 밖에 공기환경 부문에서는 제도의 운영상 예비인증시 친환경 건축자재 적용여부 및 환기시스템 적용 등에 따라 등급이 설정되어 운영되고 있으나, 향후 본인증시에는 성능기준지표를 사용함으로써 거주자 측면에서 실질적인 성능등급으로 인지될 수 있도록 제도화가 필요[37]하다는 요구사항이 있었지만 반영되지 않았다.

빛환경 부문에서는 국내 인증제에서는 평가하고 있지 않은 자연채광에 대한 요구사항이 많이 있었다. UDI9)평가를 통해 자연광의 양과 질을 평가[18], 새로운 자연채광에 대한 기준 마련[20], 자연채광 장치를 이용한 조명 제어 관련 항목 추가[26]와 같은 요구사항이 있었지만 반영되지 않았다.

또한 시각적 개방감을 창출하기 위한 경관관리 평가기준 도입[10], 일조권 간섭방지 대책의 타당성 항목을 실내환경 부문에서 평가 및 배점 상향조정[21], 고효율적인 에너지 사용과 쾌적한 환경을 위한 관리방안[25], 실내환경 시스템의 제어와 모니터링 방안[25], 열환경 및 빛환경 배점 상향조정[38]의 요구사항은 반영되지 않았다.

평가항목을 보충[5]해야 한다는 요구사항에 있어서는 2010년 개정시 교통소음에 대한 실내·외소음도, 화장실 급배수 소음 항목이 추가되었고, 2011년 개정시 단위세대의 환기성능 확보여부가 추가되었으며, 층간경계 바닥의 바닥 충격음 차단성능 항목이 경량 충격음 차단성능과 중량 충격음 차단 성능으로 분리되었다. 하지만 조명의 질에 대한 항목[26], 실내의 전반조도, 눈부심에 대한 고려[41], 외부상황 파악 가능한 조망의 확보[41], 외부로부터 시각적 프라이버시 확보[41]의 항목 신설에 대한 요구는 반영되지 않았다.

4.8.주택성능분야

주택성능분야는 2012년 친환경건축물 인증제와 주택성능등급이 일원화되면서 주택성능등급인증제 항목 대부분이 유지관리 부문으로 삽입되었으나, 2013년 개정시 주택성능분야 부문으로 분리되었다. 2013년 인증기준에서는 11개 항목으로 구성되어있으며 예비인증 평가시 성능등급표시에만 적용하고 인증평가를 위한 배점은 부여하지 않고 있다.

녹색건축물 인증제와 관련한 주택성능분야에 대한 연구는 화재항목 개발연구[19]가 있었는데 요구사항을 살펴보면, 화재 발생시 초기에 진압할 수 있는 시스템 운영 및 관리항목 신설과 방재시스템에 대한 세부항목이 필요하며, 소화기, 스프링클러, 비상경보설비, 자동화재 탐지설비 장치를 이용하여 발화요인 근거리에 비치함으로 연소 확대를 사전 방지할 수 있는 세부항목 추가, 방재시스템 설치유무에 따른 가중치 부여 및 가산점 제도 부여 항목 추가의 요구사항이 있었다. 이러한 내용들이 주택성능분야의 화재소방 항목에 어느 정도 반영되고 있었다.

4.9.소 결

녹색건축 인증제의 항목별 문제점 및 개선 요구사항에 대해 살펴보면, 에너지 및 환경오염 방지와 실내환경 부문에서 요구사항이 가장 많이 있었다. 또한 반영정도를 살펴보면 개선요구사항이 반영된 항목도 있었지만, 대체적으로 개선요구사항이 반영되지 않았다. 개선요구사항은 기존 항목에 구체적인 평가기준을 마련, 항목 개선 및 보완, 평가 기준 강화, 새로운 평가 방법 제안, 새로운 항목을 추가하는 것으로 분류 할 수 있었다.


5.결 론

본 연구에서는 공동주택의 녹색건축 인증제에 대한 선행연구를 분석하여, 개정된 인증제에 문제점 및 개선요구사항의 반영 정도를 분석하였다.

녹색건축 인증제의 평가 항목별 점수획득을 살펴보면, 점수 획득이 어려운 저득점 항목과, 획득 점수가 높은 고득점 항목으로 분류 할 수 있었다. 저득점 항목의 경우, 중요도가 높은 항목은 배점을 상향조정하여 인증항목에 대한 동기를 부여하여 평가를 받을 수 있게 해야 할 것이다. 고득점 항목의 경우, 중요도가 높은 항목들은 개정시 필수항목으로 개정되었으며, 변별력이 떨어지는 항목은 배점이 하향조정 되거나, 산출기준이 강화되었다. 향후 개정시 이러한 부분이 평가 항목에 적절하게 반영되어야 할 것이다.

녹색건축 인증제 항목별 문제점·개선 요구사항 및 반영여부에 대해 살펴보면, 선행연구에서 제안된 개선 요구사항이 반영된 항목이 있었던 반면 대체적으로 반영되지 않았다. 선행연구에서의 개선 요구사항을 분석해 보면 기존 항목에 구체적인 평가기준을 마련, 항목 개선 및 보완, 평가 기준 강화, 새로운 평가 방법 제안, 새로운 항목을 추가하는 것으로 분류 할 수 있었다.

구체적인 평가기준 마련에 대한 부분은 ‘토지이용 및 교통’부문에서 많이 있었고, 대체로 반영이 되었지만 다른 부문에서는 대체로 반영되지 않았다.

평가 기준 강화에 대한 부분은 ‘에너지 및 환경오염방지’부문에서 많이 있었고 대체로 단순히 기준을 강화해야한다는 요구사항은 반영이 되었지만, 기준 강화의 방법을 제시한 부분에서는 반영이 되지 않았다. 에너지에 대한 중요도가 높아짐에 따라 기준을 강화해야 한다는 요구가 많이 있었던 것으로 판단된다.

새로운 평가 방법을 제안하는 부분에 가장 많은 요구사항이 있었는데, 현재 평가 방법에 대한 문제에 대한 제안으로 새로운 평가 방법을 제안하거나, 해외 인증제와 비교하여 국내 인증제에 적용되지 않는 평가 방법을 제안하는 부분이 많이 있었지만 대체로 반영되지 않았다. 기존에 새로운 평가 방법을 도입하는데 평가방법을 개정하는 것 보다 많은 어려움이 따르기 때문이라고 판단된다. 새로운 항목을 추가하는 방법에는 단순히 평가항목을 추가해야한다는 부분과 구체적인 항목을 요구하는 연구로 나눌 수 있었지만, 대부분의 부문에서 새로운 항목은 추가되지 않았다.

본 연구는 공동주택의 녹색건축인증에 대한 선행연구를 분석한 것으로 향후 녹색건축 인증제의 개선방향성의 참고자료로 활용될 수 있을 것이며, 향후 전체 용도별 건축물 대상 및 제도의 운영에 대한 추가분석이 요구된다.

Glossary

1) 박상동(2009), 그린빌딩 건축계획, 기문당, p.32.

2) 녹색성장 기본법 제54조 : 정부는 에너지이용 효율 및 신·재생에너지의 사용비율이 높고 온실가스 배출을 최소화하는 건축물(녹색건축물)을 확대하기 위하여 녹색건축물 등급제 등의 정책을 수립·시행하여야 한다.

3) 녹색건축물 조성지원법 제16조 : 국토교통부장관은 지속가능한 개발의 실현과 자원절약형이고 자연친화적인 건축물의 건축을 유도하기 위하여 녹색건축 인증제를 시행한다. <개정 2013.3.23>

4) 「친환경건축물 인증기준」고시에 있는 운영기관에 대한 규정을 「녹색건축물 조성지원법」의 시행으로 제도적인 위계를 맞추기 위해 근거규정을 「녹색건축의 인증에 관한 규칙」으로 이관(2012. 11)함에 따라 본 논문에서는 ‘친환경건축물 인증’이란 용어 대신 ‘녹색건축 인증’이란 용어를 사용하고자 한다.

5) 자료 : 녹색건축 인증기준 (국토교통부·환경부공고(2013.01.16.)

6) Green Standard for Energy and Environmental Design (공모를 통해 선정 '12.12)

7) 에너지성능지표 (Energy Performance Index)

8) 총량평가방식(Performance Path) : 디자인에 제안을 받지 않은 상태에서 에너지의 총량을 만족시키는 것

9) Useful Daylight Illuminance

Acknowledgments

This paper has been studied based on the data of the Master Thesis, The Graduate School of Housing, Seoul National University of Science and Technology in 2012.

Notes

This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License(http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

This research was supported by Basic Science Research Program through the National Research Foundation of Korea(NRF) funded by the Ministry of Science, ICT and future Planning(2011-0011316)

References

  • C.H Choi, A Study on the Proper Way to Apply LEED to the Buildings in Korea and Criteria Comparison of Korean Certification of Green Building with LEED, Korean Institute of Architectural Sustainable Environment and Building Systems, (2012), 6(2).
  • S.Y Eom, O.H Song, M.H Lee, A Study on the Green Building Certification Criteria for Sustainable Urban Develo pment, Korea Planners Association, (2012), 47(1).
  • Y.S Oh, Y.J Choi,, Management Status and Suggestions for Improvement of Environment-friendly Features in GBCS- certified Apartment Communities, Architectural Institute of Korea, (2012), 28(4).
  • A.R Park, A Comparative Analysis of Acquired Score Records for Pre-certified Apartments and Office Buildings according to Green Building Certification Criteria Revisions, Architectural Institute of Korea, (2012), 28(12).
  • S.H Kim, T.G Cho, J.J Yee, A Study on the Comparative Analysis and Improvement of the Domestic and Japanese Green Building Certification Criteria by Actual Evaluation in an Apartment Complex, Journal of the Regional Association of Architectural Institute of korea, (2012), 14(2).
  • Y.H Jung, A Study on the Improvement of Green Building Rating System through Analysis of Each Assessment Item of KGBCC Certified Apartments, Architectural Institute of Korea, (2012), 28(2).
  • S.M Jung, S.J Lee, A Study on Comparing and Analyzing in Green Building Certification, Architectural Institute of Korea Conference Proceeding, (2012), 19(2).
  • K.H An, H.G Kim, Y.S Choi, A Study on Way Improvement of User-centered Green Building Certification System based on BIM, Architectural Institute of Korea, (2012), 28(1).
  • E.M Hyun, Y.S Kim,, A Comparative Study on Evaluation Methods of Energy of Green Building Certification Criteria 2010 and LEED 2009, Korea Institute of Ecological Architecture and Environ ment, (2012), 12(6).
  • S.A Han,, A Study on the Application Characteristics of Environment-Friendly Design Elements at Outdoor Spaces in Apartment Complexes, Architectural Institute of Korea, (2011), 27(4).
  • C.S Kim, A Study on the Improvement of the Maintenance Categories in Korea Green Building Certification Criteria Considering the Life cycle of Building, Korean Institute of Architectural Sustainable Environment and Conference Proceeding, (2011), 2011(10).
  • S.H Kim, Y.J Cho, J.J Yee, A Study on the Domestic System Improvement through Comparative Analysis of the South Korea Green Building Certification System and Japan CASBEE of Energy Sector of Apartment House in Busan, Korean Institute of Architectural Sustainable Environment and Building Systems Conference Proceeding, (2011), 2011(10).
  • M.S Kim, K.Y Lee, A Study on Improvement Direction of the Green-building Certifications for Energy Conservation In terms of Sustainable Architecture, Korean Institute of Architectural Sustainable Environment and Building Systems Conference Proceeding, (2011), 2011(10).
  • Y.J Kim, A Study on Improvement of the Certification Criteria in the Part of Ecological Environment in the Green Building Certification System of Apartment Complexes, Korean Journal of Environment and Ecology Conference Proceeding, (2010), 2010(1).
  • D.H Kim, D.W Cho, K.H Yu, A Study on Assessment Results of Green Building Certification Criteria According to Use, Architectural Institute of Korea, (2010), 26(1).
  • S.H Bae,, O.H Song,, A Study on the Actual Condition and the Effect of KGBCC, Architectural Institute of Korea, (2010), 26(12).
  • D.W Ko, A Study on Building Energy Efficiency Requirements of LEED 2009 and Korea Green Building Rating System : Analysis and Comparison of Energy Saving and Annual Consumption, Archite ctural Institute of Korea, (2010), 26(12).
  • H.Y Song, J.Y Lee, K.D Song, The Improvement of Daylighting Related Evaluation Items in Korea's Apartment Building Certification Systems, The Korean Society of Living Environmental System, (2010), 17(6).
  • J.H Seo, J.W Lee, T.S Lim, B.S Kim, A Study on Development of Fire Safety Items of Green Building Certification System, Korea Journal of Air-Conditioning and Refrigeration Engineering Conference Proceeding, (2010), 2010(11).
  • D.H Ko, A Study on LEED 2009 for Green Building Certification, Korean Institute of Architectural Sustainable Environment and Building Systems, (2009), 3(4).
  • R.J Oh, A Study on the Comparative Analysis and Improve ment of Indoor Environmental Factors in the Green Building Rating Systems, Korean Institute of Architectural Sustainable Environment and Building Systems, (2009), 3(2).
  • C.H Park, M.W Oh, B.S Kim, A comparative analysis study of Green Building Certification Criteria, Journal of The Korean Solar Energy Society Conference Proceeding, (2009), 2009(11).
  • Y.S Rim, J.K Kim, A Study on Developing Detailed Standards of Outdoor Spaces in Collective Housing for Sustainability Evaluation, Architectural Institute of Korea, (2009), 25(3).
  • S.N Lee, An Improvement Direction of Energy Performance Index(EPI) through Analysis of Green Building Rating Systems, Architectural Institute of Korea Conference Proceeding, (2009), 29(1).
  • M.W Kim, J.Y Chun, Comparative Analysis for Assessment of Green Building Criteria in Existing Building, Architectural Institute of Korea, (2009), 25(11).
  • J.H Kim, A Study on the Evaluation of Lighting Related Factors and Improvement of Green Building Rating System, Journal of the Korean society of living environmental system, (2008), 15(3).
  • M.S Kim, J.W Hwang, K.S Park, W.T Son, A Study on the Improvement of Assessment Criteria through Green Building Certification Cases for Apartment Houses, The Korean Society of Industrials Application Conference Proceeding, (2008), p33-36.
  • S.Y Song, Analysis of Design and Construction for the Part of Energy·Resources and Environmental Impact in the Certificated Green Apartments, Architectural Institute of Korea, (2008), 24(1).
  • H.K Kim, S.H Lee, A Case Study on the Outdoor Space of Apartment Housing in Cheongju City by Using Green Building Certification, Journal of the Institute of Constructional Technology, (2007), 26(2).
  • D.K Shin, K.H Han, Identification and Investigation of Sustainable Multi-family Housing Indicators of Domestic and Foreign Green Building Certified Systems, Architectural Institute of Korea, (2007), 23(1).
  • S.H Tae, A Study on Indoor Environmental Ratings by Comparing Green Building Certification Systems Through Case Studies, Architectural Institute of Korea, (2007), 23(8).
  • M.J Park, J.J Yee, A Study on Comparing and Analyzing Items of Domestic and Foreign Green Building Certification System, Journal of the Regional Association of Architectural Institute of korea Conference Proceeding, (2007), 2007(1).
  • S.S Go, H S, H.C Lee, A Study on the improvements of Environment-friendly Performance of Apartment Houses through Case Analysis, Architectural Institute of Korea, (2007), 23(9).
  • H.K Kim, S.H Lee, A Comparative Study on the Assessment Criteria of Environmental-Friendly Outdoor Space of Apartment Housing in Cheongju Area, Architectural Institute of Korea Conference Proceeding, (2007), 27(1).
  • H.J Kim, B,S Kim, A Study for Improvement of Green Building Rating System through POE, Korean Institute of Architectural Sustainable Environment and Building Systems, (2007), 1(2).
  • Y.Y Jung, C.H John, A comparative analysis study of Domestic and Foreign Green Building Certification Criteria's, Journal of the Regional Association of Architectural Institute of korea Conference Proceeding, (2006), 2(1).
  • S.Y Yu, Y.H Park, S.H Bae, B.S Kim, A Study on the Evaluation of the Indoor Environmental Factors and the Improvement of Green Building Rating System through the Residents' Satisfaction Survey Result, Architectural Institute of Korea, (2006), 17(12).
  • M.J Lee, A Study about Indoor Environmental Improvement of Green Building Certification System through POE, Korea Journal of Air-Conditioning and Refrigeration Engineering Conference Proceeding, (2006), 2006(6).
  • S.H Chun, S.G Oh, Contrastive Analyses of Domestic and Foreign Green Building Assessment System, Architectural Institute of Korea Conference Proceeding, (2006), 26(1).
  • S.M Lee, Comparing and Analyzing Assessment Results of Case Study by using Domestic and Foreign Green Building Certifi cation Criteria, Architectural Institute of Korea, (2005), 21(10).
  • H.J Kim, J.M Lee, A study on complement of the Green Building Rating System Criteria, Architectural Institute of Korea Conference Proceeding, (2005), 25(1).
  • E.K Hwang, The Basic Study on the Complementation of Green Building Certification Criteria in Consideration of Open Housing, Journal of the Korean housing association, (2003), 14(5).
  • K.H Kang,, Betrachtung zur Verbesserung von Green Building System, Environmental Law Association, (2008), 30(1).

Fig. 1.

Fig. 1.
Research Flowchart

Table 1.

G-SEED Outline

Act Act on development and support of green building
Enforcement
Date
1. 1. 2002
Operational
Organization
Ministry of Land, Infrastructure and Transport,
Ministry of Environment
Object Apartment, Mixed-use(Residential), Office buildings, Schools,
Commercial Facilities, Accomodations, Small Homes, Existing
Buildings(Apartments·Office),Other Buildings, Mixed-use Buildings.
Certificated
Authority
Land & Housing Institute, Korea Institute of Energy Research,
Korean Institute of Educational Environment, CrebizQM, Korea
Productivity Center, Korea Research Institute of Eco-Environmental
Architecture, Korea Infrastructure Safety Corporation, Korea Appraisal
Board, Korea Environmental Industry&Technology Institute, Korea
Green Building Council, Korea Environmental Corporation
Grade Green 1,2,3,4 grade
Categories Land use and Transportation, Energy and Prevention of
Environmental Pollution, Material and Resources, Water
Management, Maintenance, Ecological Environment

Table 2.

G-SEED Revision Contents

Date Revision Contents
2002.01.01 Enforcement of Green Building Certification Criteria (GBCC)
(Apartment Houses)
2003.01.01 Enforcement of Office and Mixed-use(Residential) criteria
2005.03.01 Enforcement of Schools criteria
2006.04.11 Revision of Apartment Houses criteria
2006.09.01 Enforcement of Commercial Facilities and Accomodations criteria
2010.07.01 -Enforcement of Other Buildings and Mixed-use Buildings,
-Strengthen Professionalism of Certification Institution, Improvement
of the timing and process, Subdivision of the grade, Revision of
the items, methods and standards
2012.07.01 -Combine G-SEED and Housing Performance Rating System
-Acquire more than Green 2 grade obligatorily for the Public
Office Buildings. (total floor area over 10,000㎡)
-Enforcement of Small Homes and Existing Buildings
(Apartments Houses·Office) Criteria
2013.02.23 -Revision of Housing Performance sector
-Change Act, Expand the obligatory acquire of Public
Buildings, Set the expiration date, Reestablish the Categories,
-Change the Certification and Mark

Table 3.

Obtained Score of Item

Items Items*
Low-Scored High-Scored
Land
Use
&
Transpo
rtation
The ecological value of the existing land 16
Existing natural resource preservation rate 6,15,16
Systematic upper plan establishment 6,15,16
Right of light 6,16
Create level of the community center and
facility spaces
16
Create the pedestrian walkway in the complex 6
Link the network of external pedestrian walkway 4,6,15
Proximity of public transportation 4
Create the bicycle storage and bike paths 4,6
Level of high-speed communication facilities 4,6,15,16
Distance of city, region and complex 4,6,15
Energy Energy Performance (Consumption) 28
Alternative Energy Use 28 6
Material
& Resources
Flexibility 28
Validity of living furniture using control measures 6,15,16,28
Separate collection of recyclable resources 15,28
Reducing food waste 28
Use the eco-friendly certified products for
recycling of valid resources
15,16,28
Saving material and resources of main
structure elements reuse of existing building
6,15,16
Saving material and resources of nonstructureelements reuse of existing building 6,15,16
Water
Manage
ment
Validity of rainwater load saving measures 28
Validity of water for living saving measures 15,16,28
Rainwater Use 16,28
Water reuse system establishment 4,6,15,16,28
Mainten
ance
Rationality of site management plan of
considering the environment
5,6,15
validity of providing the operation /
maintenance document and guidance
4,6,15,16
Provide user manual 4,6,15,16
Ecologi
cal
Environ
ment
Create the linked green network 6
Create the biotop 16
Surface soil reuse ratio 6,15,16
Indoor
Environ
ment
Use of the low-content material of
hazardous substances
6,15,16
Adapt thermostat for each room 6,15,16
Sound insulation performance of heavy and
lightweight impact noise
4
Sound insulation performance of partition
wall between housing unit
6
Acoustical environment in the complex 6,16
Indoor and outdoor noise level 4

Table 4.

Land Use and Transportation

Items Improvement Requirements Check Requirements Reflection
The ecological value of
the existing land
Required to mention of specific standards that ascertainable
ecological conservation of the existing site [27]
Ο Add standard('10) : Site of the low ecological value (development
district of residential site, large-scale development business district, coast
and wetland landfill)
Existing natural resource
preservation rate
Required to maintain (Delete '10) [3] × -
Floor area ratio Need improvement and supplementation [34] Ο Delete('10)
Right of light Suggest the appraisal criteria for the adjacent land
conditions [27]
× Level 1-5 ► 1-4 ('12)
Create level of the
community center and
facility spaces
Add specific contents for space (sort, scale, range)
[3,23,27]
Ο -Whether to plan the community center facility ► Create level of the
community center and facility spaces('12), / - Level 1-2 ► 1-4
-Add a standard('12) : community space area, residents' common space
Quality evaluation rather than quantity evaluation [23] × Calculated based on the area
Create the bicycle
storage and bike paths
Required to specific calculate standard (location) [3] × Level 1-2 ► 1-4, Strengthen standard('12)
Adequate segregation of pedestrian and vehicle [29] Ο Add standard to calculate ('10)
Required to link with complex outside [29] × Bicycle can pass from complex doorway to bicycle storage.('10)
Level of high-speed
communication facilities
Exclude the items of low sustainable influence [35] Ο Delete('10)

Table 5.

Land Use and Transportation

Improvement Requirements Check Requirements Reflection
Suggest the new evaluation standards of land use and transportation [2]
Establish the public transportation system and improve the accessibility /
Development of appropriate density and secure infrastructure/ Site selection and conservation/
Create the pedestrian network / Create the safety environment in crime and disaster
× -
Space accessibility : suggest the evaluation standards through the simulation for the moving distance and assess in the complex [8] × -
Required to minimize the impact on the external environment that occurs under construction [22] × -
Minimize the development of existing ecological environment through the land reuse [25] × -
Required to specific land use plan and space creation of transportation [25] × -
Add items and supplementation : Heat island effect and light pollution reduction [32] × -

Table 6.

Energy and Prevention of Environmental pollution

Items Improvement Requirements Check Requirements Reflection
Energy
Performan
ce
Calculating the EPI from heating and cooling loads [5] × -
Strengthen standard : to increase the substantive energy efficiency [9] × Level 1-7 ► 1-4 ('12)
Thermal transmittance : calculate the loads (CASBEE) [12] × -
Need the standard of consumption through the whole building energy
simulation [17]
× -
Required to analysis of the specific energy consumption through the energy
simulation and EPI (refer to the consumption per unit area) (LEED) [17]
× -
Strengthen standard of the building openings considering increase the
saving rate of building energy by using the proper window area and
high efficiency windows [17]
Ο 10-30% strengthen insulation standards to reduce energy consumption
of heat and cooling energy (wall, roof, floor, window and door)
Exterior wall insulation thickness (over 85㎜), Windows (pair glass
level) ► Exterior wall insulation thickness (over 120㎜), Windows
(low-e pair glass level) ('13)
Need improvement of EPI with Performance Path [24] × -
Subdivision of evaluation items and inclusion of details [35,36,40] × -
Life Cycle Assessment of energy (CASBEE : Building thermal loads, Natural
energy utilization, Efficiency in building service system, Efficient Operation) [36]
× -
Required to introduce the energy consumption evaluation methods, not a
EPI evaluation [40]
× Apply a favorable score either EPI or the Building Energy
Efficiency Rating Evaluation
Add items, Strengthen standards: commissioning, daylight equipment, etc.[40] × -
Need prerequisite item of Energy sector [43] Ο Energy Consumption(evaluation item) ► Energy Efficiency
(prerequisite item) ('10)
New·
Renewable
Energy
Raise the ratio of installation [3]
Strengthen standard [333]
△ Alternative Energy (additional item) ► New·Renewable Energy
(evaluation item) ('10)
Strengthen standard('10) : installation ratio of new·renewable energy
equipment(5~1%) / Level 1-5 ► 1-4 ('12)
CO2
emission
reduction
Energy consumption evaluation considering the life cycle [9] × ▷ Revision the evaluation methods
Evaluate by calculating either using the cogeneration system over 20%
of heating loads or CO2 emission of energy source ('02-06)
Evaluate the system that can reduce CO2 emission whether to apply('10)
▷ Revision the calculation standard
2points : Responsible for more than 15% of thermal quantity (heating
and hot water system) by using the cogeneration system. ('12)
Propose the standard considering system life cycle (Operation and
maintenance phase of building life cycle account for the large portion
of greenhouse gas emissions) [9]
×
Education for the seriousness of environmental pollution by CO2[33] ×
Consider ways to reduce CO2 emission through the cogeneration system [33] ×
Required to calculate the LCCO2 base on the life cycle of building(CASBEE) [5] × -
Required to additional consideration for the environmental pollution arise from buildings [7] × -
Rise the score of Environmental pollution sector or subdivision of evaluation items [35] × -

Table 7.

Material and Resources

Items Improvement Requirements Check Requirements Reflection
Separate
collection
of
recyclable
waste
Required to revise the evaluation considering
actual method of separate collection [3]
× -
Required to specific additional explanation
(storage facilities plan) [27]
Ο Change the scale of the waste storage facilities : over 8㎡ per 150 units ('06)
Closed space with door (over 8㎡ per 150 units) ('10)
Need additional consideration for the recycling
facilities and waste disposal facilities [33]
× Not mentioned the recycling facilities and waste disposal facilities ('13)
Reducing
food waste
Required standards for the collection container of
a food waste and position of pick up space [3]
△ ▷ Revision the evaluation methods
Evaluate whether install the storage, equipment, food waste-disposal unit or not ('02)
Evaluate the facilities for food waste separate collection and reduction plan ('06)
▷ Revision the contents (calculation standard level 2)
In case of preparation for food waste pickup area or installation of the reduction
equipment per units ('06)
In case of preparation for food waste divided pickup area considering odor and aesthetic('10)
▷ Food waste pickup area should be made to the roof structure to cover the snow and rain ('10)
Level 1-2 ► 1-4 ('12)
Evaluation whether to use the existing materials [5]
Reuse and use the recycable materials [41]
△ Only evaluated when remodeling
Sustainable purchase environment management plan [25] × -
Efficient management plan of recyclable waste [25] × -
Measurement of material performance and monitoring [25] × -
Required to consider the items for the recycling : material
reuse, use of FSC certified wood [32]
× -
Add items [41]
5-1. Building safety and longevity (add)
Plan development considering life cycle changes(move from 2-2)
Validity of care the disabled and the elderly (move from 4-4)
Module design (new) / Design for Disaster Prevention (new)
Design for security (new)
5-2 The shape of building (add)
Harmony with the surrounding buildings (new)
Secure of the buffer zone (new)
× Validity of care the disabled and the elderly : Delete ('10)
Module design : Not reflected
Design for Disaster Prevention and security : add 8. Housing Performance
Harmony with the surrounding buildings, Secure of the buffer zone : Not reflected
Change Categories : Energy Resources and Environmental
loads (Saving Resources) (2002) [42]
▷ Saving Resources
Use the eco-friendly products
Validity of living furniture using control measures
Apply eco-friendly construction methods and new technologies
▷ Diversity·Flexibility
Structure design with non-interfere of space flexibility
Core and public facility space design
Whether to apply the infill components of space flexibility
System controllability by location changes of space flexible
components
× Material and Resources (2013)
3.1.1 Flexibility
3.2.1 Validity of living furniture using control measures
3.3.1 Separate collection of recyclable resources
3.3.2 Reducing food waste
3.4.1 Use the eco-friendly certified products for recycling of valid resources
3.4.2 Display information of material carbon footprint
3.4.3 Saving material and resources of main structure elements reuse of existing building
3.4.4 Saving material and resources of non-structure elements reuse of existing building

Table 8.

Water Management

Items Improvement Requirements Check Requirements Reflection
Validity of
rainwater
load saving
measures
Add a standard to calculate for the artificial ground [27] × -
Required to improve : install the pervious pavement
in terms of water resources [33]
Ο ▷ Revision the evaluation methods
Evaluate whether to install the pervious pavement, rainwater cisterns or rainwater
treatment systems (`02)
Evaluate the installation ratio of pervious paving area ('06)
Evaluate the linked area ratio of rainwater runoff reduction facilities ('10)
Pervious paving area ► Evaluate the linked area ratio of rainwater runoff reduction facilities ('10)
Level 1-2 ► 1-4 (`12) / 3 points ► 4 points ('13)
Rainwater
Use
Required to evaluate the application of filtering
equipment and water-conveyance equipment [3]
× 2 points ► 3 points ('10) / Level 1-3 ► 1-4 (Strengthen standard) ('12)
3 points ► 4 points ('13)
Waste water
reuse system
Required to review the need of the evaluation item
(effectiveness of sustainable effects of the water reuse system)[3]
× Additional Item (4 points) ► Evaluation Item (3 points) ('10)

Table 9.

Maintenance

Items Improvement Requirements Check Requirements Reflection
Validity of providing the
operation/maintenance
document and guidance
Include the contents of certification
obligatorily in the items [3]
× Evaluation item (3points) ► Prerequisite item (2points) : strengthen standard('10)
level 1-2 ► 1-4 ('12)
Add evaluation items [5] Ο New items('12) : Ease of repair (Private space, Public space), Inclusive design,
Home-network, Security safety, Fire protection, Refuge safety
Required to consider the maintenance ('12 : enhance portion) [13] Ο Move to categories of housing performance('13) : Inclusive design,
Home-network, Security safety, Fire protection, Refuge safety
Need the systematic management system and program [33] × -
Obligation of building commissioning [1125] × -
Measurement and verification of actual data by monitoring [1125] × -
Feedback system for optimal environmental performance [1125] × -
Add items economics-related items
(Life cycle cost, Construction cost, Maintenance cost) [40]
× -

Table 10.

Ecological Environment

Items Improvement Requirements Check Requirements Reflection
Create the
linked green
network
Revision of area weighting evaluation (linked green network
in complex) [14]
× Weighting evaluation of sum and ratio (green network length and site
outline)
Revision of length weighting evaluation (green network outside
complex) [14]
× -
Required to mention of specific standards
(range of ecological corridors and linkages) [27]
× Delete the mention of ecological corridors ('10)
Green space
ratio
Subdivision of green space ratio and natural ground ratio [14] △ New item : Natural ground green area ratio(evaluation item 2points)('10)
Evaluation with ratio of natural ground green in the site (exclude the
artificial ground and rooftop garden)
Add standard (elevation area of surrounding landscape and
green space ratio in complex) [34]
× -
Apply vegetation
technique of
artificial
environment
Need maintenance plan [3] × -
Need maintenance manual development, provision and
education of landscape facilities [3]
× -
Combine the evaluation of ecological area ratio weighting
(rooftop, walls, retaining wall, fence) [14]
△ New item : Ecological area ratio (Prerequisite item 10points) ('10)
Create the
biotop
Strengthen the evaluation standard of area [14] Ο Combine the items of aquatic biotop and terrestrial biotop ('10)
Strengthen standard (area), Revision the calculation method ('10)
Add items in composition technique : Linkages, Maintenance [14] Ο Add items in Biotop : Species, Linkages, Maintenance ('10)
Revision the calculation method ('10)
Need specific evaluation standard (choice of species standards
and prerequisite of biotop) [27]
× -
Create the
aquatic biotop
Required to consider the post management (introduction of
purification system, supply water to a streamlet, etc. [3]
× -
Surface soil
reuse ratio
Rise the score and approval of circulation use [14] × Delete ('10)
Need supplementation (Ecological environment : large proportion and high
score of entire criteria) [29]
Ο 13% ('06) ► 10% ('10)

Table 11.

Indoor Environment

Items Improvement Requirements Check Requirements Reflection
Use of low volatile
organic compound
emitting materials
(2002)
Scoring depend on the finishes and when
using the 100% [21]
△ Use of the low-content material of hazardous substances : evaluation item (6 points) ('06)
Scoring depend on the finishes : finishing materials, adhesive, interior materials
Low-emitting materials : apply at least 30% of the surface area
Use the low-emitting materials of indoor air pollutants : prerequisite item (6points,
minimum 4.0 points) ('10)
Low-emitting materials : apply at least 70% of the surface area (strengthen standard)
Use the low-emitting products of indoor air pollutants : prerequisite item (6points,
minimum 4.8 points) ('12)
Specify a range of application and
strengthen standards [31]
Ο
Restriction of other
hazardous substances
emitting from materials
Proposed simulation evaluation [1] × Add item : check whether to use ('10)
Delete ('13)
(Natural ventilation
performance)
Secure the
Natural ventilation
Add standard : using the number of natural
ventilation based on act (0.7ACH), not a
area ratio [8]
Ο Secure the natural ventilation ('11) / 10~15% (level 1-2) ► 10~16% (level 1-4) ('11)
Secure the ventilation performance per units (evaluation items 3points) : check the
installation of ventilation system ('11)
Add item considering the depth of space[38] × -
Add item : requirements of the result of
ventilation through the simulation [38]
× -
Adapt thermostat for
each room
Proposed simulation evaluation [1] × Level 1-3 ► 1-4 ('11)
Secure rate of
daylight in units
evaluation of the unit rate (secure daylight)
+ consideration of optimal daylight rate +
secure the views through windows [41]
× Evaluation of the unit rate(%) : continuous daylight at least 2 hours during 6 hours ► calculate the each direction weight on distance between buildings and window
area ratio ('11)
Validity of care the
disabled and the elderly
Apply specific and diversity standard [21] × Delete ('10)
Air environment : use the performance standard indicator
(main-certification) [37]
× -
Light environment : evaluate with UDI (evaluate considering
quality and quantity of daylight) [18]
× -
Light environment : add standard of daylight (quality and quantity evaluation,
propose the minimum and maximum value of indoor illumination [20]
× -
Light environment : add item of lighting control using the daylight system [26] × -
Introduction of landscape management evaluation standard (Create a
visual openness) [10]
× -
Right of light : evaluate on the indoor environment sector, rise the score [21] × Right of light : evaluate the land use and transportation sector
Use the high efficiency energy and manage [25] × -
Control and monitoring of indoor environment system [25] ×
Rise the score : thermal and light environment : [38] × -
Add items [5], Quality of lighting [26], Secure visible views [41]
Interior illuminance, glare consideration [41]
Secure visual privacy from the outside [41]
△ Indoor and outdoor noise level for the traffic noise, Toilet plumbing noise ('10)
Secure the ventilation performance of units ('11)
Sound insulation performance of heavy and lightweight impact noise ('11)